Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: a prospective, intra-individual comparative analysis with digital subtraction angiography.

نویسندگان

  • Winfried A Willinek
  • Marcus von Falkenhausen
  • Markus Born
  • Jürgen Gieseke
  • Tobias Höller
  • Thomas Klockgether
  • Hans J Textor
  • Hans H Schild
  • Horst Urbach
چکیده

BACKGROUND AND PURPOSE Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis remain unclear. We aimed to intra-individually compare high-spatial-resolution CE 3D MRA and digital subtraction angiography (DSA) for the assessment of steno-occlusive vascular disease of the supra-aortic arteries. METHODS CE MRA and DSA of the supra-aortic arteries were prospectively performed in 50 consecutive patients. Intra-individual comparison of CE MRA and DSA was available in 833 arteries. High-spatial-resolution CE MRA comprised a measured voxel size of 0.81 mm x 0.81 mm x 1 mm (0.66 mm3). Steno-occlusive vascular disease of the 833 arteries was assessed independently by 2 radiologists according to the NASCET criteria. RESULTS CE MRA had a sensitivity of 100% (73/73), a specificity of 99.3% (760/765), a positive predictive value of 93.6% (73/78), and a negative predictive value of 100% (760/760) by using a 70% to 99% threshold of arterial diameter stenosis. For detection of occlusion, sensitivity, specificity, PPV, and NPV value of CE MRA were 100%, respectively. CONCLUSIONS Noninvasive high-spatial-resolution CE MRA is suited to replace diagnostic DSA for the detection of steno-occlusive disease of the supra-aortic arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Constructive interference in steady state imaging of moyamoya disease.

The diagnostic accuracy of three-dimensional constructive interference in steady state (CISS) magnetic resonance (MR) imaging was evaluated for the assessment of idiopathic moyamoya disease. Six consecutive patients underwent MR angiography, CISS imaging, and digital subtraction angiography. MR angiography and CISS imaging visualization of the steno-occlusive changes in the distal internal caro...

متن کامل

Three-Dimensional Dynamic Subtraction Contrast Enhanced Magnetic Resonance Angiography of the peripheral arteries--an initial experience.

This is a prospective study with the objective of comparing Three Dimensional (3D) Dynamic Subtraction Contrast Enhanced Magnetic Resonance Angiography (3DDSCEMRA) with Conventional Catheter Arteriography (CCA) as the gold standard, in the diagnosis of peripheral occlusive disease. Three patients scheduled for CCA in this hospital in between September and October 2000 were included in this stud...

متن کامل

A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced) and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

PURPOSE To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionall...

متن کامل

Angiographic Correlates of Cerebral Hemodynamic Changes With Diamox Challenge Assessed by Quantitative Magnetic Resonance Angiography.

BACKGROUND AND PURPOSE Impaired cerebrovascular reserve in chronic steno-occlusive disease has been shown to be associated with poor leptomeningeal collaterals (LMCs) on digital subtraction angiography and increased stroke risk. We examined the relationship between the degree of LMCs and the flow change with Diamox challenge measured using quantitative magnetic resonance angiography (QMRA). M...

متن کامل

Gadolinium-enhanced magnetic resonance angiography, digital subtraction angiography and duplex of the iliac arteries compared with intra-arterial pressure gradient measurements.

PURPOSE to compare gadolinium-enhanced magnetic resonance angiography (Gd-MRA), digital subtraction angiography (DSA) and duplex of the iliac arteries with intra-arterial pressure gradient measurement as the reference method. MATERIALS AND METHODS Gd-MRA, DSA and duplex examinations of the iliac arteries were performed in 30 patients (60 arteries) with lower-limb arterial occlusive disease. I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2005