Index matching to improve optical coherence tomography imaging through blood.
نویسندگان
چکیده
BACKGROUND Most myocardial infarctions are caused by the rupture of small rather than large plaques in the arteries of the heart that are beyond the detection limit of current technologies. METHODS AND RESULTS Recently, optical coherence tomography (OCT) has demonstrated considerable potential as a method for high-resolution assessment of vulnerable plaque. However, intravascular OCT imaging is complicated by the need to remove blood from the imaging field because blood results in substantial signal attenuation. This work examines index matching as a method for increasing penetration. Index matching is based on the hypothesis that the predominant source of scattering in blood is the difference in refractive index between the cytoplasm of erythrocytes and serum. By increasing the refractive index of serum to a value near that of the cytoplasm, or index matching, scattering can be substantially reduced. The concept was tested with a system that pumped blood in vitro through transparent tubing. The test compounds, dextran and intravenous contrast agent, both led to significant improvements in penetration (69+/-12% and 45+/-4%). No significant effect was seen with the saline control. For dextran, the effect could not be attributed to reductions of red cell number or volume because changes in these parameters were not different from the control. In the case of intravenous contrast, a small but significant relative reduction in red cell volume was seen. CONCLUSIONS This study demonstrates the feasibility of index matching for improving OCT imaging through blood. Future studies are required to identify compounds for effective index matching in vivo.
منابع مشابه
Optofluidic needle probe integrating targeted delivery of fluid with optical coherence tomography imaging.
We present an optofluidic optical coherence tomography (OCT) needle probe capable of modifying the local optical properties of tissue to improve needle-probe imaging performance. The side-viewing probe comprises an all-fiber-optic design encased in a hypodermic needle (outer diameter 720 μm) and integrates a coaxial fluid-filled channel, terminated by an outlet adjacent to the imaging window, a...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملOptical clearing of flowing blood using dextrans with spectral domain optical coherence tomography.
Spectral domain optical coherence tomography (SDOCT) images have been used to investigate the mechanism of optical clearing in flowing blood using dextrans. The depth reflectivity profiles from SDOCT indicate that dextrans become increasingly more effective in reducing scattering in flowing blood, except for 5 mgdl(-1) of Dx500, with increasing molecular weights (MW 70,000 and 500,000) and conc...
متن کاملExperimental Visualization of Labyrinthine Structure with Optical Coherence Tomography
Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...
متن کاملInterstitial Doppler optical coherence tomography.
Doppler optical coherence tomography (OCT) can image tissue structure and blood flow at micrometer-scale resolution but has limited imaging depth. We report a novel, linear-scanning, needle-based Doppler OCT system using angle-polished gradient-index or ball-lensed fibers. A prototype system with a 19-guage (diameter of approximately 0.9 mm) echogenic needle is constructed and demonstrates in v...