A new use for an old Holter monitor: an ambulatory cough meter.

نویسندگان

  • A B Chang
  • R G Newman
  • P D Phelan
  • C F Robertson
چکیده

Cough is commonly used as an outcome measure in clinical studies, although the subjective reporting of cough is unreliable when compared to objective measures. We describe an inexpensive new ambulatory cough meter that is based on a disused Holter monitor. The cough meter consists of a Holter monitor and a cough processor, designed on a computer to select the most appropriate filters. The cough meter was then validated against the overnight tape recorder on 21 occasions in 18 children (aged 6-15 yrs). The agreement between the cough meter and the tape recorder was good (mean difference of -0.3 coughs x h(-1); limits of agreement -2.2 to 1.7 coughs x h(-1)). We conclude that our newly described ambulatory cough meter provides a valid and inexpensive method of objectively monitoring cough for up to 24 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subjective scoring of cough in children: parent-completed vs child-completed diary cards vs an objective method.

Cough is often used as an outcome measure, although the reporting of cough is unreliable. Using a 24 h ambulatory cough meter to measure cough frequency, the aim of this study was to compare: 1) the correlation of child-completed diary cards to the objective measurement, with that of parent-completed diary cards; and 2) the visual analogue scale (VAS) to the verbal category descriptive (VCD) sc...

متن کامل

A Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure

In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...

متن کامل

Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours.

BACKGROUND To compare simultaneous recordings from an external patch system specifically designed to ensure better P-wave recordings and standard Holter monitor to determine diagnostic efficacy. Holter monitors are a mainstay of clinical practice, but are cumbersome to access and wear and P-wave signal quality is frequently inadequate. METHODS This study compared the diagnostic efficacy of th...

متن کامل

Methods for Ambulatory Arrhythmia Monitoring A Comparison Study of Holter Monitor and Chest Strap ECG A Prospective Pilot Study

Background Cardiac arrhythmias, including atrial fibrillation (AF), are a common cause for seeking medical care. AF has many causes; where valvular disease, hypertension, heart failure and diabetes mellitus are among the most common ones. The golden standard for arrhythmia monitoring is a 24or 48-hours Holter monitor. The aim with this paper was to compare the Holter monitor with chest strap EC...

متن کامل

Evaluation of a new self-contained, ambulatory, objective cough monitor

OBJECTIVE AND BACKGROUND Objective monitoring of cough may be preferred to subjective reporting of the symptom in clinical and research settings. Therefore, a self-contained, ambulatory cough monitoring system is needed that is non-invasive, usable for children and adults of all ages, inexpensive, and highly accurate with easy to use analysis software. METHODOLOGY After development of a new d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 7  شماره 

صفحات  -

تاریخ انتشار 1997