Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?
نویسندگان
چکیده
BACKGROUND Exhaled nitric oxide is a non-invasive marker of airway inflammation and a portable analyser, the NIOX MINO (Aerocrine AB, Solna, Sweden), is now available. This study aimed to assess the reproducibility of the NIOX MINO measurements across age, sex and lung function for both absolute and categorical exhaled nitric oxide values in two distinct groups of children and teenagers. METHODS Paired exhaled nitric oxide readings were obtained from 494 teenagers, aged 16-18 years, enrolled in an unselected birth cohort and 65 young people, aged 6-17 years, with asthma enrolled in an interventional asthma management study. RESULTS The birth cohort participants showed a high degree of variability between first and second exhaled nitric oxide readings (mean intra-participant difference 1.37 ppb, 95% limits of agreement -7.61 to 10.34 ppb), although there was very close agreement when values were categorised as low, normal, intermediate or high (kappa = 0.907, p < 0.001). Similar findings were seen in subgroup analyses by sex, lung function and asthma status. Similar findings were seen in the interventional study participants. CONCLUSIONS The reproducibility of exhaled nitric oxide is poor for absolute values but acceptable when values are categorised as low, normal, intermediate or high in children and teenagers. One measurement is therefore sufficient when using categorical exhaled nitric oxide values to direct asthma management but a mean of at least two measurements is required for absolute values.
منابع مشابه
[Measurement of fraction of exhaled nitric oxide with the portable NIOX-MINO monitor in healthy adults].
Measurement of the fraction of exhaled nitric oxide (FENO) provides a noninvasive way to monitor asthma treatment in clinical practice. The aim of this study was to determine FENO reference values for measurements recorded with the portable NIOX MINO monitor in a group of healthy volunteers. We also assessed the association between values recorded by the portable monitor and the N-6008 chemilum...
متن کاملReliability of a new hand-held device for the measurement of exhaled nitric oxide.
BACKGROUND Given the importance of airway inflammation in asthma, there has been an effort to incorporate inflammatory markers into its management. Measurement of fractional exhaled nitric oxide (FeNO) is a noninvasive marker of airway inflammation; however, the use of the available FeNO analyzer is limited by several factors including its cost and lack of transportability. The aim of this stud...
متن کاملAssessment of exhaled nitric oxide by a new hand-held device.
BACKGROUND Fractional exhaled nitric oxide (FENO) has been implicated as a pulmonary biomarker. The aim of this study was to compare the performance of a new hand-held device to a standard chemiluminescence analyzer and to another portable device. METHODS FENO levels measured by NObreath (Bedfont) were compared to those of (1) a chemiluminescence detector (Logan, Logan Research) and (2) the e...
متن کاملValidation of a New Portable Exhaled Nitric Oxide Analyzer, NIOX VERO®: Randomized Studies in Asthma
Introduction: Fractional exhaled nitric oxide (FeNO) is a non-invasive marker of airway inflammation, and a new portable analyzer (NIOX VERO ) is now available. Our studies aimed to assess the agreement of measurements between NIOX VERO and a reference device (NIOX MINO ) and assess the reproducibility of NIOX VERO . Methods: Paired FeNO readings were obtained from 112 subjects from both device...
متن کاملPerformance of a new hand-held device for exhaled nitric oxide measurement in adults and children
BACKGROUND Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary he...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2010