Comminuted supracondylar femoral fractures: a biomechanical analysis comparing the stability of medial versus lateral plating in axial loading

نویسندگان

  • Nikolai Briffa
  • Raju Karthickeyan
  • Joshua Jacob
  • Arshad Khaleel
چکیده

The aim of this study was to compare the biomechanical properties of medial and lateral plating of a medially comminuted supracondylar femoral fracture. A supracondylar femoral fracture model comparing two fixation methods was tested cyclically in axial loading. One-centimetre supracondylar gap osteotomies were created in six synthetic femurs approximately 6 cm proximal to the knee joint. There were two constructs investigated: group 1 and group 2 were stabilized with an 8-hole LC-DCP, medially and laterally, respectively. Both construct groups were axially loaded. Global displacement (total length), wedge displacement, bending moment and strain were measured. Medial plating showed a significantly decreased displacement, bending moment and strain at the fracture site in axial loading. Medial plating of a comminuted supracondylar femur fracture is more stable than lateral plating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of plate rotation on the stiffness of femoral LISS: a mechanical study.

OBJECTIVE Malposition of the femoral Less Invasive Stabilization System (LISS) plate may alter its biomechanical behavior. This study compares the mechanical stability of "correctly" affixed LISS plates matching the slope of the lateral femoral condyle to "incorrectly" placed LISS plates fixed in external rotation relative to the distal femur. METHODS A fracture gap model was created to simul...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

Mono- versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate

BACKGROUND The aim of this cadaveric study was to compare a polyaxial (NCB®, Zimmer) to a fixed-angle monoaxial locking plate (PERILOC®, Smith & Nephew) in comminuted fractures of the distal femur regarding stability of the construct. Up to date there is no published biomechanical data concerning polyaxial plating in cadaveric distal femurs. METHODS Fourteen formalin fixed femora were scanned...

متن کامل

Biomechanical Evaluation of Two Methods of Humeral Shaft Fixation

This study compared the biomechanical performance of 4.5-mm limited-contact dynamic compression plates and 3.5-mm locking compression plates for the fixation of unstable humeral shaft fractures. Composite humeri were divided into two groups: 3.5mm LC and 4.5-mm LCDC plates. Osteotomy gaps of 5-mm, simulating diaphyseal comminution, were created. Stiffness tests were performed in anterior-poster...

متن کامل

Anatomical plate configuration affects mechanical performance in distal humerus fractures.

BACKGROUND Because of strong loads acting in the elbow joint, intraarticular fractures with a methaphyseal comminuted fracture site at the distal humerus demand a lot from the osteosynthetic care. Ambiguities arise concerning to the anatomic position of the implants and the resulting mechanic performance. The aim of this biomechanical study was to compare the performance of different anatomical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016