Detection and sequencing of new cyclic peptides from linseed by electrospray ionization mass spectrometry.
نویسنده
چکیده
Extract of Linum usitatissimum seeds was analyzed by ESI-MS and ESI-MS/MS. The analysis confirms the presence of previously reported cyclolinopeptides: CLA (c(Pro-Pro-Phe-Phe-Leu-Ile-Ile-Leu-Val) and CLB (c(Pro-Pro-Phe-Phe-Val-Ile-Met-Ile-Leu)). Cyclolinopeptides CLD and CLE, which contain methionine oxide, were detected in small quantities only. These peptides likely result from the oxidation of their precursors, not reported previously: CLD' (c(Pro-Phe-Phe-Trp-Ile-Met-Leu-Leu)) and CLE'(c(Pro-Leu-Phe-Ile-Met-Leu-Val-Phe)), present at higher concentrations in unoxidized extract. Two new cyclic octapeptides: CLF (c(Pro-Phe-Phe-Trp-Val-Met-Leu-Met)) and CLG (c(Pro-Phe-Phe-Trp-Ile-Met-Leu-Met)) were detected and their sequences were proposed on the basis of CID experiments and similarity with those of CLD'.
منابع مشابه
Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملSolvent-free mass spectrometry for hydrophobic peptide sequence analysis and protein conformation studies.
The breakthrough in soft ionization methods for biopolymers, electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) (1,2), revolutionized mass spectrometry (MS). As a result of these effective bioanalytical technologies, the entire field of proteomics changed, and the use of mass spectrometers for protein identification by accurate mass measurements or de novo seq...
متن کاملDirect sequencing of a disulfide-linked peptide with electrospray ionization tandem mass spectrometry.
Dissociation of disulfide is normally mandatory prior to disulfide peptide sequencing via electrospray ionization collision induced dissociation mass spectrometry (ESI-CID-MS). Herein, a facile method for directly sequencing intact disulfide peptides was proposed. The basic principles involved were electrolyte-enhanced corona discharge in ESI and the following oxidative cleavage reaction.
متن کاملPeptides Labeled with Pyridinium Salts for Sensitive Detection and Sequencing by Electrospray Tandem Mass Spectrometry
Mass spectrometric analysis of trace amounts of peptides may be problematic due to the insufficient ionization efficiency resulting in limited sensitivity. One of the possible ways to overcome this problem is the application of ionization enhancers. Herein we developed new ionization markers based on 2,4,6-triphenylpyridinium and 2,4,6-trimethylpyridinium salts. Using of inexpensive and commerc...
متن کاملElectrospray-assisted laser desorption ionization mass spectrometry (ELDI-MS) with an infrared laser for characterizing peptides and proteins.
An electrospray-assisted laser desorption/ionization source with an infrared OPO laser (IR-ELDI) was constructed and optimized for peptide and protein mass spectrometry analysis. Similar to ELDI with an ultraviolet laser, IR-ELDI generates multiply charged molecules for peptides and proteins measured under ambient sampling conditions. Both samples in the dried state and analyte solutions can be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta biochimica Polonica
دوره 48 4 شماره
صفحات -
تاریخ انتشار 2001