Indications and techniques of locked plate fixation for the treatment of challenging fractures continue to evolve. As design variant of classic locked plates, the polyaxial locked plate has the ability to alter the screw angle and thereby, enhance fracture fixation. The aim of this observational study was to evaluate clinical and radiographic results in 89 patients with 90 fractures of the distal femur treated, between June 2006 and November 2011, with such a polyaxial locked plating system (Polyax™ Locked Plating System, DePuy, Warsaw, IN, USA). Seventy-seven fractures formed the report of this study. These cases were followed up until complete fracture healing or for a mean time of 77 weeks. At the time of last follow-up, 58 of 77 fractures (75.3 %) progressed to union without complication and radiographic healing occurred at a mean time of 16.3 weeks. Complications occurred in ten fractures that did not affect the healing and in nine fractures that showed delayed or non-union. The mean American Knee Society Score at the time of final follow-up was 83 for the Knee Score and 71.1 for the Functional Score. In conclusion, there is a high union rate for complex distal femoral fractures associated with a good clinical outcome in this series.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison.

OBJECTIVES Uniaxial, first-generation locking plates have become increasingly popular for fixation of supracondylar femur fractures. Polyaxial plates are currently available, which allow for variable-angle screw insertion; however, the biomechanical integrity of these new locking constructs is yet unproven. This study compares the mechanical stability of a conventional locking plate with that o...

متن کامل

Mono- versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate

BACKGROUND The aim of this cadaveric study was to compare a polyaxial (NCB®, Zimmer) to a fixed-angle monoaxial locking plate (PERILOC®, Smith & Nephew) in comminuted fractures of the distal femur regarding stability of the construct. Up to date there is no published biomechanical data concerning polyaxial plating in cadaveric distal femurs. METHODS Fourteen formalin fixed femora were scanned...

متن کامل

Mid Term Results of Distal Femoral Fractures Treated with a Polyaxial Locking Plate: A Multi-Center Study

OBJECTIVE Locking plates have become a standard implant in the treatment of distal femoral fractures. Newer designs allow polyaxial screw placement as well as the ability to lock the lag screws. METHODS The consecutive multi-centre study cohort consists of all distal femoral fractures treated with the NCB® Distal Femur plate (Zimmer, Warsaw, USA) and a minimum follow-up of twelve months. Frac...

متن کامل

Peri-Implant Fractures Distal to an Antegrade Femoral Nail: A Case Series

Peri-implant fractures distal to an antegrade femoral nail are uncommon injuries, with no current consensus on the best treatment modality. We are presenting three cases of periimplant fractures distal to an antegrade femoral nail. All patients sustained an initial traumatic injury, which was managed with an antegrade femoral nail fixation. They subsequently suffer a second injury which causes ...

متن کامل

Polyaxial versus uniaxial volar locking plate for distal radial fractures.

PURPOSE To compare the penetration of the distal screws in relation to the thickness of the distal metaphysis in the polyaxial versus uniaxial volar locking plates. METHODS Records of 78 patients aged 16 to 79 years who underwent open reduction and internal fixation for distal radial fractures (n=81) were reviewed. All fracture subtypes were included. 20 men and 22 women aged 18 to 79 (mean, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014