Digital Analysis of Sit-to-Stand in Masters Athletes, Healthy Old People, and Young Adults Using a Depth Sensor
نویسندگان
چکیده
The aim of this study was to compare the performance between young adults (n = 15), healthy old people (n = 10), and masters athletes (n = 15) using a depth sensor and automated digital assessment framework. Participants were asked to complete a clinically validated assessment of the sit-to-stand technique (five repetitions), which was recorded using a depth sensor. A feature encoding and evaluation framework to assess balance, core, and limb performance using time- and speed-related measurements was applied to markerless motion capture data. The associations between the measurements and participant groups were examined and used to evaluate the assessment framework suitability. The proposed framework could identify phases of sit-to-stand, stability, transition style, and performance between participant groups with a high degree of accuracy. In summary, we found that a depth sensor coupled with the proposed framework could identify performance subtleties between groups.
منابع مشابه
Cardiac baroreflex function and dynamic cerebral autoregulation in elderly Masters athletes.
Cerebral blood flow (CBF) is stably maintained through the combined effects of blood pressure (BP) regulation and cerebral autoregulation. Previous studies suggest that aerobic exercise training improves cardiac baroreflex function and beneficially affects BP regulation, but may negatively affect cerebral autoregulation. The purpose of this study was to reveal the impact of lifelong exercise on...
متن کاملAcceleration of Upper Trunk Coordination in Young Versus old Adults During Walking on the Level and Irregular Floor Surface Using MTx Sensor
Objectives: To evaluate the reliability of head and trunk acceleration measured by MTx sensors during walking on Level and Irregular surfaces and to compare the differences between healthy young and old adults. Methods: Participants were 20 young female university students and 20 non-faller elderly women in Iran, 2013. Two MTX sensors were used to measure head and trunk accelerations in the ...
متن کاملEffect of Handrail Height on Sit-To-Stand Movement
BACKGROUND Care-needing older adults and disabled individuals often require handrails for assistance of movements, such as sit-to-stand movements. Handrails must be set at the appropriate position; however, the effects of handrail height on joint movement and center-of-gravity movements during sit-to-stand movement remain unclear. In the present study, we sought to clarify the effects of handra...
متن کاملAutomated approach for quantifying the repeated sit-to-stand using one body fixed sensor in young and older adults.
Much is known about the sit-to-stand (STS) and its biomechanics. Currently, however, there is little opportunity for instrumented quantification of the STS as part of screening or diagnosis in clinical practice. The objectives of the present study were to describe the feasibility of using an automated approach for quantifying the STS using one sensor location and to start testing the discrimina...
متن کاملTest-retest reliability of sensor-based sit-to-stand measures in young and older adults.
This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2018