Radiation hardness of the PIBETA detector components

نویسندگان

  • E. Frlež
  • T. A. Campbell
  • I. J. Carey
  • D. Počanić
چکیده

We have examined long term changes in signal amplitude gain, energy resolution and detection efficiency for the active components of the PIBETA detector system. Beam defining plastic scintillation counters were operated in a ∼ 1 MHz stopped π + beam for a period of 297 days, accumulating radiation doses of up to 2 · 10 6 rad. Detectors in the charged particle tracking system—a pair of cylindrical multi-wire proportional chambers and a thin plastic scintilla-tion barrel-shaped hodoscope array—were irradiated during the same running period with an average dose of ∼ 4 · 10 4 rad. Individual CsI(undoped crystal) calorimeter detectors received an average dose of ∼ 120 rad, mainly from pho-tons, positrons and protons originating from π + hadronic interactions as well as from π + and µ + weak decays at rest in the active target.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The automatic gain-matching in the PIBETA CsI calorimeter

Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as the spatial and energy resolutions are affected differently. Increased number of individual detectors reduces accidental particle pile-up per detector but int...

متن کامل

ADC common noise correction and zero suppression in the PIBETA detector

We describe a simple procedure for reducing ADC common noise in modular detectors that does not require additional hardware. A method using detector noise groups should work well for modular particle detectors such as segmented electromagnetic calorimeters, plastic scintillator hodoscopes, cathode strip wire chambers, segmented active targets, and the like. We demonstrate a “second pedestal noi...

متن کامل

ar X iv : h ep - e x / 03 12 02 5 v 1 8 D ec 2 00 3 Absolute Branching Ratio Normalization for Rare π + and μ + Decays in the PIBETA Experiment

We have used the PIBETA detector at the PSI for a precise measurement of rare pion and muon weak decays. We have collected a large statistical sample of (1) π

متن کامل

Measurement of stopping beam distributions in the PIBETA detector

Precise calculation of the geometrical acceptance of a large solid angle detector with an integrated stopping target relies on precise knowledge of the beam geometry. We describe four alternative methods that we used to measure the beam stopping distributions in the PIBETA detector active target: (i) light response of segmented target elements to incident beam particles, (ii) backtracking of ch...

متن کامل

ar X iv : h ep - e x / 03 12 02 5 v 2 1 0 D ec 2 00 3 Absolute Branching Ratio Normalization for Rare π + and μ + Decays in the PIBETA Experiment

We have used the PIBETA detector at the PSI for a precise measurement of rare pion and muon weak decays. We have collected a large statistical sample of (1) π

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002