The use of immobilized enzyme reactors in continuous-flow analyzers for the determination of glucose, urea, and uric acid.

نویسندگان

  • R Chirillo
  • G Caenaro
  • B Pavan
  • A Pin
چکیده

We describe the use of immobilized enzymes in assay methods for the determination of glucose with glucose oxidase, uric acid with uricase, and urea with urease in serum samples. The enzyme reactor tubes were adapted to continuous-flow analyzers (Technicon AA II, SMA 12/60, and SMAC) used in routine laboratory determinations, and results with their use were compared to those from assays involving soluble enzymes. We substituted the reactors for the free enzyme reagents in the respective channels of the SMA 12/60 and SMAC, without modifying the parameters of the remaining channels. We compared assay sensitivity, precision, and carryover for immobilized and conventional liquid enzymes. Immobilized enzyme reactors provide accurate, reliable, convenient, and economical alternatives to the use of free enzyme reagents in these systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immobilized uricase for automated assay of uric acid in serum

The wide use of bound enzyme coils with hexokinase and glucose-6-phosphate dehydrogenase in automated analysis for serum-glucose assay [1, 2-] demonstrates the potential of open tubular heterogeneous enzyme reactors [3] in clinical analysis. Such reactors have also been prepared with other enzymes I-4, 5] and in this paper the authors describe a continuous-flow method for uric acid assay with i...

متن کامل

Immobilized enzymes in continuous-flow analysis.

Glucose oxidase, uricase, and urease were immobilized on the interior surface of activated polyamide tubing. The shelf-life of such enzyme bearing tubes was at least six months. The tubes were used for continuous-flow analysis of glucose, uric acid, and urea with conventional systems and with hybrid micro-scale systems in which modules of different manufacture were combined. The length of enzym...

متن کامل

Bioaffinity Based Immobilization of Almond (Amygdalus communis) b-galactosidase on Con A-layered Calcium Alginate-cellulose Beads: Its Application in Lactose Hydrolysis in Batch and Continuous Mode

In this study, immobilization of partially purified almond (Amygdalus communis) β-galactosidase on Con A layered calcium alginate-cellulose beads was investigated. Immobilized β-galactosidase retained 72% of theinitial activity after crosslinking by glutaraldehyde. Both soluble and immobilized enzyme exhibited the samepH and temperature optima at pH 5.5 and 50ºC, respectively. Howev...

متن کامل

Single- and coupled-enzyme nylon-tube reactors for plasma glucose determination with glucose oxidase and aldehyde dehydrogenase.

We describe routine methods for determining glucose in plasma with use of aldehyde dehydrogenase or glucose oxidase-aldehyde dehydrogenase immobilized in a nylon tube that is integrated into a continuous-flow system. Although the coupled-enzyme nylon-tube reactors require the presence of a third enzyme, catalase, in solution, the kinetics are not so complicated as to preclude reliable routine d...

متن کامل

Immobilized-enzyme nylon-tube reactors for routine determination of urea and citrulline in serum.

A continuous-flow clinical analyzer for the routine estimation of urea is described that makes use of an immobilized-enzyme nylon-tube reactor as part of a flow-through system (a Technicon AutoAnalyzer I). Results of blood-urea analyses by use of the immobilized urease are compared with determinations made with the diacetyl monoxime method and the urease solution method. Clinical trials carried...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 10  شماره 

صفحات  -

تاریخ انتشار 1979