The effect of complete tenotomy on blood flow to the anterior segment of the canine eye.
نویسندگان
چکیده
The relative importance of the anterior ciliary arteries to blood flow to the anterior segment and the quadrant distribution of blood to the iris, ciliary body, and ciliary processes were determined in canines with the use of 15 +/- 3 mum 103Ru microspheres with the reference blood flow method. Recti muscles were isolated in both eyes. Then with one eye serving as a sham-operated control, anterior ciliary artery blood flow was disrupted by recti tenotomy immediately prior to microsphere injection. Tenotomy resulted in a significant decrease in blood flow to the anterior segment (0.14 +/- 0.03 ml/min/gm vs. 0.26 +/- 0.05 in the untenotomized control) and to the unit iris, ciliary body and ciliary processes (I, CB, CP) (0.92 +/- 0.16 ml/min/gm vs. 1.44 +/- 0.22 in the untenotomized control). Blood flow values for the anterior segment and the unit I, CB, CP in the tenotomized eye were 50% to 60% of those of the control eyes, indicating that the majority of blood flow to the canine anterior segment is not disrupted by complete tenotomy. In the control eye, blood flow values for the medial quadrant of the unit I, CB, CP were significantly higher (p < 0.05) than those of the inferior or superior quadrants. Blood flow values for all quadrants in tenotomized eyes were 55% to 70% of those for control eyes. Therefore the anterior ciliary arteries do not contribute the majority of blood flow to the canine anterior segment.
منابع مشابه
A Numerical Analysis for the Effect of Slip Velocity and Stenosis Shape on Non-Newtonian Flow of Blood (TECHNICAL NOTE)
The aim of this paper is to study the effect of slip velocity and shape of stenosis on non-Newtonian flow of blood through a stenosed arterial segment. Blood is modeled as Bingham-Plastic fluid in a uniform circular tube with a radially non-symmetric stenosis. The problem is investigated by a joint effort of analytical and numerical techniques. The influence of stenosis shape parameter, slip ve...
متن کاملEffects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer
To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...
متن کاملNumerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues
Introduction: The present study aimed to present a numerical analysis of the penetration depth, specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...
متن کاملPurtscher’s Retinopathy in a Patient with Falling Down: A Case Report
Purpose: To report a case of Purtscher’s Retinopathy in a patient with falling down. Case Report: A 25-year-old man with no history of specific disease referred to the ophthalmology clinic of Imam Hossein Hospital 2 days after falling due to a sudden vision loss in his right eye. Best-corrected visual acuity was counting finger 1m in the right and 10/10 in the left eye and Marcus Gunn pupil was...
متن کاملA Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform
Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 19 11 شماره
صفحات -
تاریخ انتشار 1980