Ozone detection by differential absorption spectroscopy at ambient pressure with a 9.6 μm pulsed quantum-cascade laser

ثبت نشده
چکیده

We report direct absorption spectroscopic detection of ozone at ambient pressure with a pulsed, DFB quantumcascade laser (QCL) tuned within 1044–1050 cm−1 by temperature scanning. Wavelength calibration curves were derived from FTIR and CO2 spectra and interpreted with respect to the heat transfer from the heterostructure to the sink. The laser linewidth (∼ 0.13 cm−1 FWHM) was found to decrease with temperature, probably as a result of operation at constant current. Spurious spectral features due to baseline inaccuracies were successfully filtered out from the QCL O3 spectra using differential absorption. Reference O3 concentrations were obtained by applying the same method to UV spectra, simultaneously measured with a differential optical absorption spectrometer (DOAS). Column densities retrieved from QCL spectra are in fairly good agreement (±20%) with the DOAS values above 28 ppm m. The estimated QCL lowest detectable, absolute and differential absorptions, (7×10−3 and 2×10−3, respectively), entail effective detection limits of 14 and 25 ppm m, respectively. Ongoing improvements in the acquisition system should allow the achievement of detection limits at the level of commercial open-path DOAS systems (∼ 2 ppm m) in the near future. Our results demonstrate the applicability of the differential absorption method to QCL spectroscopy at ambient pressure, and encourage its use for open path detection. PACS 42.62.Fi; 82.80.Gk; 92.60.Sz

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Application of Uv-visible and Mid-ir Differential Absorption Spectroscopy Techniques for Pollutant Trace Gas Monitoring

We report direct absorption spectroscopic detection of ozone at ambient pressure with apulsed, DFB quantum-cascade laser (QCL) tuned within 1044-1050 cm by temperaturescanning. Wavelength calibration curves were derived from FTIR and CO2 spectra andinterpreted with respect to the heat transfer from the heterostructure to the sink. The laserlinewidth (~0.13 cm FWHM) was found...

متن کامل

Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas

We report on the development of a photoacoustic sensor for the detection of formaldehyde (CH(2)O) using a thermoelectrically cooled distributed-feedback quantum cascade laser operating in pulsed mode at 5.6 μm. A resonant photoacoustic cell, equipped with four electret microphones, is excited in its first longitudinal mode at 1,380 Hz. The absorption line at 1,778.9 cm(-1) is selected for CH(2)...

متن کامل

Recent Advances in Trace Gas Detection Using Quantum and Interband Cascade Lasers

There is an increasing need in many chemical sensing applications ranging from environmental science to industrial process control as well as medical diagnostics for fast, sensitive, and selective trace gas detection based on laser spectroscopy. The recent availability of novel pulsed and continuous wave (cw) quantum and interband cascade distributed feedback (QC and IC DFB) lasers as mid-infra...

متن کامل

There is an increasing need in many chemical sensing applications ranging from industrial process control to environmental sci

There is an increasing need in many chemical sensing applications ranging from industrial process control to environmental science and medical diagnostics for fast, sensitive, and selective gas detection based on laser spectroscopy. The recent availability of novel pulsed and cw quantum cascade distributed feedback (QC-DFB) lasers as mid-infrared spectroscopic sources address this need. A numbe...

متن کامل

Trace-gas detection in ambient air with a thermoelectrically cooled, pulsed quantum-cascade distributed feedback laser.

A pulsed quantum-cascade distributed feedback laser operating at near room temperature was used for sensitive high-resolution IR absorption spectroscopy of ambient air at a wavelength of approximately 8 microm. Near-transform-limited laser pulses were obtained owing to short (approximately 5-ns) current pulse excitation and optimized electrical coupling. Fast and slow computer-controlled freque...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004