Correction: Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)

نویسندگان

  • Armin Biller
  • Morwan Choli
  • Martin Blaimer
  • Felix A. Breuer
  • Peter M. Jakob
  • Andreas J. Bartsch
چکیده

PURPOSE To compare a novel combined acquisition technique (CAT) of turbo-spin-echo (TSE) and echo-planar-imaging (EPI) with conventional TSE. CAT reduces the electromagnetic energy load transmitted for spin excitation. This radiofrequency (RF) burden is limited by the specific absorption rate (SAR) for patient safety. SAR limits restrict high-field MRI applications, in particular. MATERIAL AND METHODS The study was approved by the local Medical Ethics Committee. Written informed consent was obtained from all participants. T2- and PD-weighted brain images of n = 40 Multiple Sclerosis (MS) patients were acquired by CAT and TSE at 3 Tesla. Lesions were recorded by two blinded, board-certificated neuroradiologists. Diagnostic equivalence of CAT and TSE to detect MS lesions was evaluated along with their SAR, sound pressure level (SPL) and sensations of acoustic noise, heating, vibration and peripheral nerve stimulation. RESULTS Every MS lesion revealed on TSE was detected by CAT according to both raters (Cohen's kappa of within-rater/across-CAT/TSE lesion detection κCAT = 1.00, at an inter-rater lesion detection agreement of κLES = 0.82). CAT reduced the SAR burden significantly compared to TSE (p<0.001). Mean SAR differences between TSE and CAT were 29.0 (± 5.7) % for the T2-contrast and 32.7 (± 21.9) % for the PD-contrast (expressed as percentages of the effective SAR limit of 3.2 W/kg for head examinations). Average SPL of CAT was no louder than during TSE. Sensations of CAT- vs. TSE-induced heating, noise and scanning vibrations did not differ. CONCLUSION T2-/PD-CAT is diagnostically equivalent to TSE for MS lesion detection yet substantially reduces the RF exposure. Such SAR reduction facilitates high-field MRI applications at 3 Tesla or above and corresponding protocol standardizations but CAT can also be used to scan faster, at higher resolution or with more slices. According to our data, CAT is no more uncomfortable than TSE scanning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the role of specific absorption rate of mobile phones on the induction of microwave-induced survival adaptive responses after exposure to lethal doses of gamma radiation

Background: Whether exposure to common electromagnetic fields affects human health adversely has been a controversial issue. The main goal of this study was to assess the role of 900 MHz microwave radiations with different specific absorption rates (SARs), emitted from some widely used cell phones, on the induction of adaptive response in male Balb/c mice after receiving a lethal dose of gamma ...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

High-Resolution, Low-SAR T2 Imaging at High Magnetic Fields

The PSIF (gradient-reversed FISP, SSFP, CE-FAST) sequence is demonstrated to produce high-quality, T,-weighted images in human brain at magnetic field strengths of 4 Tesla and above In contrast to spin-echo or multiple-echo imaging techniques commonly used in clinical practice at lower fields, the importance of Bi homogeneity in PSIF imaging is minimal and the average RF power deposition is low...

متن کامل

Effectiveness of psychological training combined ‎with gradual muscular stress relaxation technique on quality of life of patients with multiple sclerosis

Background: Multiple sclerosis (MS) is one of the most common chronic diseases of the central nervous system. The aim of this study was to determine the effectiveness of psychological training combined&lrm; with gradual muscular stress relaxation technique on QOL of patients with MS. Materials and Methods: This triple-blind, controlled, clinical trial was conducted on 60 patients with MS who...

متن کامل

Investigation of Acoustic Properties of Polymer Nanocomposites regarding Combined Sound Absorption and Insulation Characteristics

Introduction: Nowadays multiple techniques have been developed to noise control. One the most important way is the control based on sound absorption and insulation. The purpose of current study was to improve the acoustic properties of soft polyurethane foam regarding combined sound absorption and insulation characteristics. Materials and Methods: Polyacrylonitrile and polyvinylidine fluoride ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014