An impedance method for blood pressure measurement in awake rats without preheating.
نویسندگان
چکیده
The tail-cuff methods for measuring systolic blood pressure in the rat usually require preheating of the animal to obtain recordable pulse signals. To find a more sensitive method, we applied the principle of differentiated impedance (dZ/dt) to the tail-cuff measurement of systolic blood pressure. We obtained clear pulse signals from the tail in awake rats without preheating the animals, and the systolic blood pressure obtained by this method had an excellent correlation with the directly measured femoral artery pressure (correlation coefficient = 0.98). Heating the animals at 40 degrees C for 5 minutes increased systolic blood pressure by a mean of 6 mm Hg as compared with that determined at the ambient temperature of 21 to 24 degrees C. Mean systolic blood pressure in young female diabetic rats was 122 +/- 3 mm Hg, which was significantly higher than the 111 +/- 2 mm Hg of normal rats. It is concluded that the technique of electrical impedance as applied to the tail-cuff method is simple and highly sensitive and is suitable for measurement of tail systolic blood pressure in awake rats without preheating.
منابع مشابه
Tail-cuff blood pressure measurement without external preheating in awake rats.
A new photoelectric sensor capable of detecting tail pulses even in unheated rats was tested for accuracy in indirect measurements of blood pressure. This sensor proved more sensitive than a Doppler ultrasonic flowmeter because it allowed detection not only of tail pulsations without preheating but also of peak oscillations usable for estimating mean arterial pressure. After blood pressures in ...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملMeasuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
The CODA 8-Channel High Throughput Non-Invasive Blood Pressure system measures the blood pressure in up to 8 mice or rats simultaneously. The CODA tail-cuff system uses Volume Pressure Recording (VPR) to measure the blood pressure by determining the tail blood volume. A specially designed differential pressure transducer and an occlusion tail-cuff measure the total blood volume in the tail with...
متن کاملبرآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید
Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hypertension
دوره 11 4 شماره
صفحات -
تاریخ انتشار 1988