A pilot biomechanical assessment of curling deliveries: is toe sliding more likely to cause knee injury than flatfoot sliding?

نویسندگان

  • Iona Robertson
  • Graham P Arnold
  • Weijie Wang
  • Tim S Drew
  • Sadiq Nasir
  • Calum MacDonald
  • Rami J Abboud
چکیده

BACKGROUND The aim of this study was to determine whether toe sliding is more likely to cause knee injuries than flatfoot sliding in curling. METHODS Twelve curlers participated in the study, each delivering 12 stones. Six stones per volunteer were delivered using a flatfoot slide and six were delivered using a toe slide. The Pedar-X in-shoe pressure system recorded the plantar pressure during each of the slides, while a sagittal plane digital video recorded the body position of the curler. Measurements were taken from the video recordings using a software overlay program (MB Ruler), and this, combined with the Pedar-X data, gave the overall joint force in the tuck knee. RESULTS The knee joint force for toe sliding was more than double that of flatfoot sliding (p<0.05). There was a strong correlation between the increase in knee joint force and the increase in the moment arm of the ground reaction force. Images produced using the three-dimensional Vicon system confirm that toe sliding produces a larger moment arm than flatfoot sliding. CONCLUSION Injuries are more likely to occur in toe sliding, compared with flatfoot sliding, due to the increase in force and moment, pushing the weight of the curler forward over the knee, which could make the adopted position less stable. Curlers might consider avoiding toe sliding to reduce the risk of knee injuries if the two types of delivery could be performed equally well.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A biomechanical assessment of the sliding motion of curling delivery in elite and subelite curlers.

The present study examined the technical characteristics of sliding performance from push-off until stone release in curling delivery. Five elite performance level curlers (> 7 years experience) and five subelite level curlers (< 3 years experience) were analyzed during the action of delivery of a curling stone. The joint angles, angular velocities, and moments of the body center of mass (COM) ...

متن کامل

The effect of foot landing position on biomechanical risk factors associated with anterior cruciate ligament injury

BACKGROUND Identification of biomechanical risk factors associated with anterior cruciate ligament (ACL) injury can facilitate injury prevention. The purpose of this study is to investigate the effects of three foot landing positions, "toe-in", "toe-out" and "neutral", on biomechanical risk factors for ACL injury in males and females. The authors hypothesize that 1) relative to neutral, the toe...

متن کامل

A Computer Simulation of Tuned Pid and Continuous Sliding Mode Fes Control

Functional Electrical Stimulation can restore movement in certain paralyzed individuals. Electric current pulses excite the intact peripheral nerves, cause the muscles to contract and generate joint movements. Since this physiological and biomechanical system is highly nonlinear and time-varying, feedback control is necessary for satisfactory FES control of the joint angles. In this study, a co...

متن کامل

Optimal Robust Control for a Series Elastic Actuator assisting Knee Joint

Rehabilitation and assistive systems such as rotary series elastic actuators (RSEA) should provide the desired torque precisely. In this paper, to improve the life quality of those who suffer from weak knees, the control problem of a rotary series elastic actuator (RSEA) has been studied in order to generate soft human walking motion. These actuators produce the require torque, but the nonlinea...

متن کامل

Dynamic Sliding Mode Control of Nonlinear Systems Using Neural Networks

Dynamic sliding mode control (DSMC) of nonlinear systems using neural networks is proposed. In DSMC the chattering is removed due to the integrator which is placed before the input control signal of the plant. However, in DSMC the augmented system is one dimension bigger than the actual system i.e. the states number of augmented system is more than the actual system and then to control of such ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017