Enantiomer-specific analysis of multi-component mixtures by correlated electron imaging–ion mass spectrometry
نویسندگان
چکیده
Simultaneous, enantiomer-specific identification of chiral molecules in multi-component mixtures is extremely challenging. Many established techniques for single-component analysis fail to provide selectivity in multi-component mixtures and lack sensitivity for dilute samples. Here we show how enantiomers may be differentiated by mass-selected photoelectron circular dichroism using an electron-ion coincidence imaging spectrometer. As proof of concept, vapours containing ∼1% of two chiral monoterpene molecules, limonene and camphor, are irradiated by a circularly polarized femtosecond laser, resulting in multiphoton near-threshold ionization with little molecular fragmentation. Large chiral asymmetries (2-4%) are observed in the mass-tagged photoelectron angular distributions. These asymmetries switch sign according to the handedness (R- or S-) of the enantiomer in the mixture and scale with enantiomeric excess of a component. The results demonstrate that mass spectrometric identification of mixtures of chiral molecules and quantitative determination of enantiomeric excess can be achieved in a table-top instrument.
منابع مشابه
Phosphatidylethanolamine-induced cholesterol domains chemically identified with mass spectrometric imaging.
Coexisting liquid phases of model membrane systems are chemically identified using imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS). The systems studied were Langmuir-Blodgett (LB) model membranes of cholesterol (CH) with two different phospholipids, one a major component in the outer plasma membrane bilayer leaflet (dipalmitoylphosphatidylcholine (PC)) and the other a major co...
متن کاملNanoflow LC/IMS-MS and LC/IMS-CID/MS of protein mixtures.
A simple ion trap/ion mobility/time-of-flight (TOF) mass spectrometer has been coupled with nanoflow liquid chromatography to examine the feasibility of analyzing mixtures of intact proteins. In this approach proteins are separated using reversed-phase chromatography. As components elute from the column, they are electrosprayed into the gas phase and separated again in a drift tube prior to bei...
متن کاملHigh-field asymmetric-waveform ion mobility spectrometry and electron detachment dissociation of isobaric mixtures of glycosaminoglycans.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is shown to be capable of resolving isomeric and isobaric glycosaminoglycan negative ions and to have great utility for the analysis of this class of molecules when combined with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and tandem mass spectrometry. Electron detachment dissociation (EDD) and other ion...
متن کاملHexuronic acid stereochemistry determination in chondroitin sulfate glycosaminoglycan oligosaccharides by electron detachment dissociation.
Electron detachment dissociation (EDD) has previously provided stereo-specific product ions that allow for the assignment of the acidic C-5stereochemistry in heparan sulfate glycosaminoglycans (GAGs), but application of the same methodology to an epimer pair in the chondroitin sulfate glycoform class does not provide the same result. A series of experiments have been conducted in which glycosam...
متن کاملAtomic spectrometry update. Atomic mass spectrometry
1. Accelerator mass spectrometry (AMS) 1.1. Reviews 1.2. AMS systems 1.3. Methodology 1.4. Developments in radiocarbon analysis 1.5. Developments in the measurement of elements other than carbon 2. Electrospray mass spectrometry (ESMS) 3. Gas chromatography-electron ionization mass spectrometry (GC-EIMS) 4. Glow discharge mass spectrometry (GDMS) 4.1. Reviews 4.2. Instrumentation 4.3. Analytica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2015