Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the peak current is proportional to the concentration of pioglitazone HCl, and a linear calibration graphs were obtained within the concentration levels of 10(-8) and 10(-4) M following different accumulation time periods (0-300 s). The obtained results were analyzed and the statistical parameters were calculated. The detection limit is 8.08 × 10(-9) M (3.17 ng ml(-1)) using 300 s pre-concentration time, whereas the quantitative limit is 2.45 × 10(-8) M (9.63 ng ml(-1)). The proposed method was applied to assay the drug in pharmaceutical formulations and biological fluids. The pharmacokinetic parameters of drug in human plasma were estimated as: C max=785.8 ng ml(-1), t max=1.5 h, K e=0.125 h(-1) and t 1/2=8 h which are favorably compared with those reported in literature.
منابع مشابه
Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملAdsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملDetermination of ultra trace of thiosemicarbazide by adsorptive stripping voltammetric method
In the present work, an adsorptive stripping voltammetric method using a hanging mercurydrop electrode (HMDE) was described in order to determine the ultra trace of thiosemicarbazidein different real samples. The method is based on accumulation of thiosemicarbazide on mercuryelectrode. The potential was scanned to the negative direction and the differential pulse strippingvoltammograms were rec...
متن کاملSimultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid
In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...
متن کاملAdsorptive Stripping Anodic Voltammetric Determination of Thioctic Acid in Bulk and Pharmaceutical Formulations
The electrochemical behavior of thioctic acid at the hanging mercury drop electrode was studied in different supporting electrolytes. In Britton - Robinson buffer pH 3.29, the square - wave adsorptive anodic stripping voltammogram of thioctic acid exhibited a single well - defined anodic peak at about -0.21 V vs Ag/AgCl. The peak response was characterized with respect to pH, preconcentration t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2008