Feasibility of RF Ablation at the Larmor Frequency for RF Field Visualization

نویسندگان

  • K. Shultz
  • P. Stang
  • J. Pauly
  • G. Scott
چکیده

Introduction: Radiofrequency ablation is an effective minimally invasive treatment for tumors. One primary source of difficulty is monitoring and controlling the ablation region. MR currently has a role in RF ablation due to its capability for temperature monitoring. RF ablation is typically performed at 480 kHz. If instead the ablation were to be performed at the Larmor frequency, then the MR capability for B1 field mapping could be used to directly visualize the RF fields created by the ablation currents. Visualizing the RF fields may enable better control of the ablation currents, enabling better control of lesion shape and size and improving repeatability. We demonstrate the feasibility of performing RF ablations at 64 MHz and show preliminary results from imaging the RF fields from the ablation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Volumetric Radiofrequency Current Density Imaging

Introduction: Radiofrequency current density imaging (RFCDI) measures currents at the Larmor frequency [1]. It is potentially useful for applications such as predicting and monitoring RF ablation treatment patterns or measuring the effectiveness of pacemaker insulators. Currents at the Larmor frequency create magnetic fields that act as an effective B1 field, exciting magnetization. By measurin...

متن کامل

کاربرد انرژی رادیوفرکونسی در درمان آریتمی AVNRT

AV-node modification by catheter RF energy delivery is treatment of choice in the symptomatic patients with AVNRT. This study included 30 patients with AVNRT (19 women, 11 men). We did slow pathway ablation in 29 cases successfully. Maximum effective energy delivery was 40 watts for 40 msec. 1:1 AV conduction increased from 290±40 msec before ablation to 340±65 msec after ablation. Also AV-node...

متن کامل

Comparing the Efficacy of Temperature-Controlled Radiofrequency Tonsil Ablation versus CO2-Laser Cryptolysis in the Treatment of Halitosis

Introduction: Halitosis and foreign body sensation are two common and disturbing symptoms of chronic caseous tonsillitis (CCT). The aim of this study was to compare the efficacy and safety of temperature-controlled radiofrequency (TC-RF) tonsil ablation with CO2-laser cryptolysis (CO2-LC) in the treatment of patients with halitosis caused by CCT.   Materials and Methods: Sixty-two patients who ...

متن کامل

Intrinsic MRI visualizes RF lesions within minutes after MR-guided ablation

Background MR visualization of RF lesions is an application of growing interest with the potential for translation to clinical ablation procedures. In particular, intrinsic-contrast MRI avoids the dynamic contrast produced in typical Gd-based MRI, and may differentiate the reversible and irreversible thermal injury thought to be caused by RF ablation. This distinction is important for assessing...

متن کامل

طراحی کاواک 100 مگاهرتز برای حلقه انبارش چشمه نور ایران

Iranian Light Source Facility (ILSF) RF system was conceptually designed based on ILSF requirements for a 3 GeV storage ring and 400 mA beam current at 500 MHz RF frequency. Considering the fact that  cavity construction is simpler at 100 MHz and advantages of reducing frequency provided an alternative of 100MHz RF system to be explored for ILSF. After a thorough study on the effect of reducing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010