Carotid plaque characterization using 3D T1-weighted MR imaging with histopathologic validation: a comparison with 2D technique.
نویسندگان
چکیده
BACKGROUND AND PURPOSE 3D FSE T1WI has recently been used for carotid plaque imaging, given the potential advantages in contrast and spatial resolutions. However, its diagnostic performance remains unclear. Hence, we compared the ability of this technique to readily assess plaque characteristics with that of conventional images and validated the results with histologic classification. MATERIALS AND METHODS We prospectively examined 34 patients with carotid stenosis who underwent carotid endarterectomy by using 1.5T scanners and obtained 3D-FSE T1WI and 2D spin-echo T1WI scans. After generating reformatted images obtained from the 3D-FSE T1-weighted images, we calculated the contrast ratios for the plaques and the adjacent muscles and compared these findings with the pathologic classifications. RESULTS Carotid plaques were histologically classified as types VII, VIII, IV-V, or VI. With 3D-FSE T1WI, the range of contrast ratios for each classification was the following: 0.94-0.97 (median, 0.95), 0.95-1.29 (median, 1.10), 1.33-1.54 (median, 1.42), and 1.53-2.12 (median, 1.80), respectively. With 2D imaging, the range of contrast ratios for each classification was the following: 0.79-1.02 (median, 0.90), 0.88-1.19 (median, 1.01), 1.17-1.46 (median, 1.23), and 1.55-2.51 (median, 2.07), respectively. Results were significantly different among the 4 groups (P < .001). Sensitivity and specificity for discriminating vulnerable plaques (IV-VI) from stable plaques (VII, VIII) were both 100% for the 3D technique and 100% and 91%, respectively, for the 2D technique. CONCLUSIONS 3D-FSE T1WI accurately characterizes intraplaque components of the carotid artery, with excellent sensitivity and specificity compared with those of 2D-T1WI.
منابع مشابه
Preoperative 3D FSE T1-Weighted MR Plaque Imaging for Severely Stenotic Cervical ICA: Accuracy of Predicting Emboli during Carotid Endarterectomy
The aim of the present study was to determine whether preoperative three-dimensional (3D) fast spin-echo (FSE) T1-weighted magnetic resonance (MR) plaque imaging for severely stenotic cervical carotid arteries could accurately predict the development of artery-to-artery emboli during exposure of the carotid arteries in carotid endarterectomy (CEA). Seventy-five patients underwent preoperative M...
متن کاملComparative Evaluations of 3d Turbo Spin Echo (tse) Motion Sensitized Driven Equilibrium (msde) and 2d Double Inversion Recovery Tse Sequences for T1-weighted Black-blood Carotid Atherosclerosis Imaging
Introduction In vivo MR carotid plaque imaging has been used to identify vessel morphology and plaque characteristics, and their associations with clinical symptoms. [1] Two-dimensional T1 weighted (T1W) double inversion recovery spin echo [2] and subsequently quadruple inversion recovery spin echo sequences [3] have been used to obtain the contrast between vessel wall and lumen, and identify c...
متن کاملSegmentation of Carotid Plaque using Multi-Contrast 3D Gradient Echo MR Imaging
Introduction: The ability to identify plaque components in atherosclerotic carotid arteries using MRI is well established [1] and is amenable to automatic segmentation with techniques such as Morphology-Enhanced Probabilistic Plaque Segmentation (MEPPS) [2]. Measurements of components, such as necrotic core (NC), calcification (CA) and loose matrix (LM) have enabled researchers to identify plaq...
متن کاملPredicting carotid plaque characteristics using quantitative color-coded T1-weighted MR plaque imaging: correlation with carotid endarterectomy specimens.
BACKGROUND AND PURPOSE MR plaque imaging is used to evaluate the risk of embolic complications during carotid endarterectomy and carotid artery stent placement. However, its performance for characterizing intraplaque components has varied across studies and is generally suboptimal. Hence, we correlated MR imaging results with histologic findings to determine whether a combination of high-contra...
متن کاملT2-prepared segmented 3D-gradient-echo for fast T2-weighted high-resolution three-dimensional imaging of the carotid artery wall at 3T: a feasibility study
BACKGROUND The multi-contrast assessment of the carotid artery wall has become an important diagnostic tool for the characterization of atherosclerotic plaque and vessel wall thickening. For providing the required T1-, T2-, and proton density weighted contrast, multi-slice turbo spin echo (TSE) techniques are normally applied. The straightforward extension of the TSE techniques to volumetric im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2015