The pupil can control an artificial lens intuitively.

نویسندگان

  • Jan Fliedner
  • Christian Heine
  • Georg Bretthauer
  • Helmut Wilhelm
چکیده

PURPOSE After cataract surgery, the ability to accommodate is lost. For this reason, a mechatronic IOL is being developed at the moment: The Artificial Accommodation System. This device requires an easily measureable indicator of the distance of the observed object to determine the demand of accommodation. As the pupil constricts with near vision, pupil size might be such an indicator. Our research focused on whether the pupil can control an artificial lens. METHODS A study with 14 healthy subjects aged between 24 and 64 years was conducted. An artificial lens with variable refractive power was mounted in front of one eye. In this eye, natural accommodation was greatly reduced or absent due to presbyopia, pseudophakia, or iatrogenic cycloplegia. The lens' refractive power was changed in a computer-controlled manner depending on changes in the pupil diameter of the second eye, which could not see the fixation stimulus. The subject's task was to get a clear focused image of the target in different distances. RESULTS The lens can be controlled by the pupil intuitively (P < 1.8 × 10(-18)). Without prior knowledge, 11/14 subjects passed the first trial, and 31/41 trials were successful. Only one subject was not able to control the lens at all. Most subjects comprehended instantly how to use the unfamiliar lens control to bring a target into focus. CONCLUSIONS This study emphasizes the plasticity of the visual control system. Positioning accuracy was acceptable, but the control must be optimized to facilitate maintaining a defined refractive power.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients

Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...

متن کامل

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

PURPOSE To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. METHODS This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of ...

متن کامل

Induced movement of receptor alignment toward a new pupillary aperture.

Bonds and MacLeod (1978) reported on an individual whose receptors, as measured by the peak of the Stiles-Crawford function, were oriented in the direction of a traumatically displaced pupil. In an attempt to demonstrate that this orientational response is caused by an active alignment process and not simply a result of passive forces due to the traumatic ocular injury, we attempted to influenc...

متن کامل

On-eye performance of custom wavefront-guided soft contact lenses in a habitual soft lens-wearing keratoconic patient.

PURPOSE To assess visual, optical, and fitting characteristics for wavefront-guided soft contact lenses produced for one habitual soft lens-wearing moderate keratoconic eye. METHODS A process for production and evaluation of custom wavefront-guided soft contact lenses was developed. Wavefront aberrations were quantified with the COAS-HD wavefront sensor (Wavefront Sciences); soft contact lens...

متن کامل

In vitro strehl ratios with spherical, aberration-free, average, and customized spherical aberration-correcting intraocular lenses.

PURPOSE To determine in vitro image qualities of artificial eyes achieved with spherical, aberration-free, average spherical aberration-correcting, and customized spherical aberration-correcting IOLs in centered, decentered, and tilted positions. METHODS The in vitro performance of these IOL models was determined by optical bench measurements. The experimental setup included a laser light sou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2014