The double orifice valve technique to treat tricuspid valve incompetence

نویسنده

  • R Hetzer
چکیده

BACKGROUND A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. METHODS A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of <1. 0m2, and 1.5 mm for a BSA of >1.0m2. RESULTS During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency or stenosis. Reoperations on three patients (mean age 42.5 ± 8.7 years) were indicated for aortic valve replacement at 14 months postoperatively (n = 1) and for assist device implantation (n = 2) who eventually underwent heart transplant at 18 and 20 months after TV repair, respectively. The cumulative 12-year survival rate was 86.9%. CONCLUSIONS This double-orifice technique is technically a straightforward repair to abolish TV incompetence with highly satisfactory results, particularly in patients with severe annular dilatation or with leaflet and chordal tethering. In the present series, the technique provided no pitfalls (if the location of the conduction system was borne in mind), requiring only a gentle placement of sutures. It also led to no residual regurgitation or reoperation during the follow up period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How to do the double orifice valve technique to treat tricuspid valve incompetence.

A straightforward tricuspid valve repair technique is illustrated here, which may be employed either for functional (normal valve with dilated annulus) or for primary or organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) tricuspid valve incompetence and for moderate and severe degrees of incompetence, without any residual regurgi...

متن کامل

Classification-based repair techniques to correct tricuspid valve incompetence in Ebstein’s anomaly and long-term functional outcome

Methods Sixty-eight (68) patients (mean age 26.9±7.3 years) with Ebstein’s anomaly (Types A=18, A=3, B=21, B-C=2, C=15, D=9) underwent correction of TV incompetence. The atrialized ventricle, the TV and subvalvar apparatus were inspected to analyze the precise morphology, and determine which leaflet was the most mobile. In all, the atrialized right ventricle (RV) is incorporated into the contra...

متن کامل

Quinticuspid aortic valve causing aortic valve incompetence and stenosis.

Aortic valve dysfunction may be the consequence of congenital malformation of the aortic valve. Unicuspid,'2 bicuspid,'-6 tricuspid,23 and quadricuspid68 aortic valves have all been described. We describe a patient who presented with cardiac enlargement caused by aortic valve incompetence and stenosis. Echocardiograms repeatedly showed multiple closing lines in the aortic valve orifice. This pa...

متن کامل

Double orifice mitral valve with dysplastic tricuspid valve and intact interatrial septum: a three-dimensional echocardiographic study.

Double orifice mitral valve is a rare congenital heart disease. We present a case in which 3D echocardiography helped clarify the underlying anatomy. The need exists for more extensive use of this technique to allow for surgical and pathological confirmation.

متن کامل

Gaillard_4255 r1.qxd:Layout 1

The edge-to-edge repair (EtER) technique was introduced in 1991 to treat both mitral regurgitation (1) and tricuspid regurgitation (2) caused by complex valvular lesions. The method involves anchoring the free edge of the diseased leaflet to the corresponding edge of the opposing leaflet, just at the place of the regurgitant jet. When the middle sections of the leaflets are sutured, a ‘double-o...

متن کامل