Effective calibration of an endoscope to an optical tracking system for medical augmented reality
نویسندگان
چکیده
Background: We investigated the methods of calibrating an endoscope to an optical tracking system (OTS) for high accuracy augmented reality (AR)-based surgical navigation. We compared the possible calibration methods, and suggested the best method in terms of accuracy and speed in a medical environment. Material and methods: A calibration board with an attached OTS marker was used to acquire the pose data of the endoscope for the calibration. The transformation matrix from the endoscope to the OTS marker was calculated using the data. The calibration was performed by moving either the board or the endoscope in various placements. The re-projection error was utilized for evaluating the matrix. Results: From the statistical analysis, the method of moving the board was significantly more accurate than the method of moving the endoscope (p < 0.05). This difference resulted mainly from the uneven error distribution in the OTS measurement range and also the hand tremor in holding the endoscope. Conclusions: To increase the accuracy of AR, camera-to-OTS calibration should be performed by moving the board, and the board and the endoscope should be as close as possible to the OTS. This finding can contribute to improving the visualization accuracy in AR-based surgical navigation. Subjects: Biomedical Engineering; Medical Imaging; Medical Technology & Engineering
منابع مشابه
Hybrid method for both calibration and registration of an endoscope with an active optical tracker
In this paper, we present a hybrid method for calibration of an endoscope and its registration with an active optical tracker. Practically, both operations are done simultaneously by moving an active optical marker in the field of view of the two devices. By segmenting image data, the LEDs composing the marker are extracted and the transformation matrix between the two referentials (homography)...
متن کاملRecovering Projection Geometry: How a Cheap Camera Can Outperform an Expensive Stereo System
Recovering the projection geometry of an X-ray system or an augmented reality video see-through Head Mounted Display (HMD) are mathematically quite similar. Recent work in both medical imaging and augmented reality use external optical sensors in order to recover the motion of the imaging system. In this paper, we take the example of the recovery of an X-ray projection geometry. We show that th...
متن کاملFlexible Calibration of Actuated Stereoscopic Endoscope for Overlay in Robot Assisted Surgery
Robotic assistance have greatly benefited the operative gesture in mini-invasive surgery. Nevertheless, the surgeon is still suffering from the restricted vision of the operating field through the endoscope. We thus propose to augment the endoscopic images with preoperative data. This paper focuses on the use of a priori information to initialise the overlay by a precise calibration of the actu...
متن کاملA Fast, Affordable System for Augmented Reality
This paper presents a framework for augmented reality. Head tracking is accomplished using a head-mounted camera, which uses an optical flow based algorithm to track patterns on the ceiling. The position and orientation of the ceiling need not be known a priori, and the necessary calibration, except for radial lens distortion, can be performed on the fly using simple procedures.
متن کاملHybrid Tracking for Augmented Reality
In augmented reality, the real world is augmented by virtual, computer generated objects. If real and virtual objects are not aligned properly, the experience of the user will not be satisfying, as the illusion of a common world consisting of both real and virtual objects will not be present. To achieve this precise alignment, it is necessary to track the user’s position and orientation with hi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017