چکیده
INTRODUCTION The orbital subarachnoid space surrounding the optic nerve is continuous with the circulation system for cerebrospinal fluid (CSF) and can be visualized by using magnetic resonance imaging (MRI). We hypothesized that the orbital subarachnoid space width (OSASW) is correlated with and can serve as a surrogate for intracranial pressure (ICP). Our aim was to develop a method for a noninvasive measurement of the intracranial CSF-pressure (CSF-P) based on MRI-assisted OSASW. METHODS The prospective observational comparative study included neurology patients who underwent lumbar CSF-P measurement and 3.0-Tesla orbital magnetic resonance imaging (MRI) for other clinical reasons. The width of the orbital subarachnoid space (OSASW) around the optic nerve was measured with MRI at 3, 9, and 15 mm behind the globe. The study population was randomly divided into a training group and a test group. After adjusting for body mass index (BMI) and mean arterial blood pressure (MABP), algorithms for the associations between CSF-P and OSASW were calculated in the training group. The algorithms were subsequently verified in the test group. Main outcome measures were the width of the orbital subarachnoid space (OSASW) and the lumbar cerebrospinal fluid pressure (CSF-P). RESULTS Seventy-two patients were included in the study. In the training group, the algorithms for the associations between CSF-P and OSASW were as follows: (a) CSF-P = 9.31 × OSASW (at 3 mm) + 0.48 × BMI + 0.14 × MABP-19.94; (b) CSF-P = 16.95 × OSASW (at 9 mm) + 0.39 × BMI + 0.14 × MABP-20.90; and (c) CSF-P = 17.54 × OSASW (at 15 mm) + 0.47 × BMI + 0.13 × MABP-21.52. Applying these algorithms in the independent test group, the measured lumbar CSF-P (13.6 ± 5.1 mm Hg) did not differ significantly from the calculated MRI-derived CSF-P (OSASW at 3 mm: 12.7 ± 4.2 mm Hg (P = 0.07); at 9 mm: 13.4 ± 5.1 mm Hg (P = 0.35); and at 15 mm: 14.0 ± 4.9 mm Hg (P = 0.87)). Intraclass correlation coefficients (ICCs) were higher for the CSF-P assessment based on OSASW at 9 mm and at 15 mm behind the globe (all ICCs, 0.87) than for OSASW measurements at 3 mm (ICC, 0.80). CONCLUSIONS In patients with normal, moderately decreased or elevated ICP, MRI-assisted measurement of the OSASW appears to be useful for the noninvasive quantitative estimation of ICP, if BMI and MABP as contributing parameters are taken into account. TRIAL REGISTRATION Clinical trial registered with the Chinese Clinical Trial Registry: ChiCTR-OCC-11001271.
منابع مشابه
Intracranial pressure (ICP) and optic nerve subarachnoid space pressure (ONSP) correlation in the optic nerve chamber: the Beijing Intracranial and Intraocular Pressure (iCOP) study.
PURPOSE Because a lowered intracranial pressure (ICP) is a possible mechanism of optic neuropathy, we wished to study the CSF dynamics in the optic nerve chamber by recording possible changes in the optic nerve subarachnoid space pressure (ONSP) and the impact on it when acutely lowering ICP. METHODS In eight normal dogs pressure probes were implanted in the left brain ventricle, lumbar ciste...
متن کاملThe effect of increased intra-abdominal pressure on orbital subarachnoid space width and intraocular pressure
In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can relieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was ...
متن کاملIntraocular pressure vs intracranial pressure in disease conditions: A prospective cohort study (Beijing iCOP study)
BACKGROUND The correlation between intracranial pressure (ICP) and intraocular pressure (IOP) is still controversial in literature and hence whether IOP can be used as a non-invasive surrogate of ICP remains unknown. The aim of the current study was to further clarify the potential correlation between ICP and IOP. METHODS The IOP measured with Goldmann applanation tonometer was carried out on...
متن کاملMagnetic resonance imaging in pseudotumor cerebri.
OBJECTIVE To determine whether magnetic resonance (MR) imaging can be used to predict the presence of elevated intracranial pressure. DESIGN Retrospective case series. PARTICIPANTS Twenty patients with pseudotumor cerebri and 20 control subjects. INTERVENTION Magnetic resonance imaging. MAIN OUTCOME MEASURES The presence or absence of the following six neuroimaging signs was measured: (...
متن کاملUveitis initiating an autoimmune reaction resulting in Goodpasture's syndrome in a Chinese man.
LETTERS Spontaneous venous pulsations should be monitored during glaucoma therapy It is well established that lowering intraocular pressure slows or halts progression of glau-coma. None the less, changes in intracranial pressure also affect the pressure gradient across the lamina cribrosa. Normal intraocu-lar pressures combined with low intracranial pressures produce the same pressure different...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2013