A new electrodynamic balance design for low temperature studies
نویسندگان
چکیده
منابع مشابه
A new electrodynamic balance design for low temperature 1 studies
15 In this paper we describe a newly designed cold electrodynamic balance (CEDB) system, 16 built to study the evaporation kinetics and freezing properties of supercooled water droplets. 17 The temperature of the CEDB chamber at the location of the levitated water droplet can be 18 controlled in the range: -40 ̊C to +40 ̊C, which is achieved using a combination of liquid 19 nitrogen cooling and...
متن کاملA new electrodynamic balance (EDB) design for low-temperature studies: application to immersion freezing of pollen extract bioaerosols
In this paper we describe a newly designed cold electrodynamic balance (CEDB) system, built to study the evaporation kinetics and freezing properties of supercooled water droplets. The temperature of the CEDB chamber at the location of the levitated water droplet can be controlled in the range −40 to +40 C, which is achieved using a combination of liquid nitrogen cooling and heating by positive...
متن کاملBalanced Acceptance Sampling+m: A Balance Between Entropy and Spatially Balance
Balanced acceptance sampling is a relatively new sampling scheme that has potential to improve the efficiency of spatial studies. There are two drawbacks of the design, it can have low entropy and some of the unbiased estimates can not be calculated. In this paper, such shortcomings have been addressed by integrating simple random sampling with balanced acceptance sampling. In a simulation stud...
متن کاملThermal Modeling for Predication of Automobile Cabin Air Temperature
Thermal modeling of an automotive cabin was performed in this paper to predict the inside cabin air temperature. To implement this task, thermal and ventilation loads were estimated and the mass and energy balance conservation equations for dry air and water vapor with considering a new parameter (air circulation ratio) as well as the balance equations of internal components of a cabin were de...
متن کاملThermally Induced Structural Changes in Coal Combustion
It has been observed that certain char particles shrink when oxidized under kinetically limited conditions, instead of reacting at constant diameter, as expected. This study was perfonned to determine whether or not char from PSOC 1451 coal, prepared at different temperatures would also shrink during low temperature gasification. Coal chars, formed at l 200K and 1600K, were levitated in the ele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014