Nonparametric Inference of Photon Energy Distribution from Indirect Measurements

نویسندگان

  • E. MOULINES
  • F. ROUEFF
  • A. SOULOUMIAC
  • T. TRIGANO
چکیده

We consider a density estimation problem arising in nuclear physics. Gamma photons are impinging on a semiconductor detector, producing pulses of current. The integral of this pulse is equal to the total amount of charge created by the photon in the detector, which is linearly related to the photon energy. Because the inter-arrival of photons can be shorter than the charge collection time, pulses corresponding to different photons may overlap leading to a phenomenon known as pileup. The distortions on the photon energy spectrum estimate due to pileup become worse when the photon rate increases, making pileup correction techniques a must for high counting rate experiments. In this paper, we present a novel technique to correct pileup, which extends a method introduced in Hall and Park (2004) for the estimation of the service time from the busy period in M/G/∞ models. It is based on a novel formula linking the joint distribution of the energy and duration of the cluster of pulses and the distribution of the energy of the photons. We then assess the performance of this estimator by providing an expression of its integrated square error. A Monte-Carlo experiment is presented to illustrate on practical examples the benefits of the pileup correction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculating Weighting Factors for Mixing Megavoltage Photon Beams to Achieve Desirable Dose Distribution in Radiotherapy

Background: In radiotherapy, low-energy photon beams are better adapted to the treated volume, and the use of high-energy beams can reduce hot spots in the radiation therapy. Therefore, mixing low and high energies with different ratios can control the rate of hotspots, as well as the dose distribution of the target volume.Material and Methods: The percentage depth doses (PDDs) were calculated ...

متن کامل

Medium-Term Stability of the Photon Beam Energy of An Elekta CompactTM Linear Accelerator Based on Daily Measurements of Beam Quality Factor

Introduction In this study, we aimed to assess the medium-term energy stability of a 6MV Elekta CompactTM linear accelerator. To the best of our knowledge, this is the first published article to evaluate this linear accelerator in terms of energy stability. As well as investigating the stability of the linear accelerator energy over a period of several weeks, the results will be useful for esti...

متن کامل

Calculating weighting factors for mixing megavoltage photon beams to achieve desirable dose distribution in Radiotherapy

Introduction: Many studies have shown the effects of delivered dose distribution due to the incident photon energy on the tumor and healthy tissues. The ability to access the most appropriate radiation energy is essential to achieve the optimal treatment planning but there is a serious limitation in number of energies available on radiation therapy machines can restrict it. <s...

متن کامل

Investigations of parameters affecting the photon energy spectra of an 18 MV Varian 2100C/D linear accelerator

Radiotherapy using linear accelerators is known as an effective modality for cancer treatment. The photons energy of treatment beams significantly affect the dose distribution. Therefore, it is important to accurately evaluate the photon energy spectra. In this study, MCNPX Monte Carlo code (version 2.6.0) was used to simulate an 18 MV photon beam of a Varian 2100C/D linear accelerator. By matc...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005