Biomechanical Comparison of Arthroscopic Single- and Double-Point Repair Techniques for Acute Bony Bankart Lesions

نویسندگان

  • Ulrich Spiegl
  • Sean Smith
  • Jocelyn Todd
  • Garrett A. Coatney
  • Coen A. Wijdicks
  • Peter J. Millett
چکیده

BACKGROUND Single- and double-row arthroscopic reconstruction techniques for acute bony Bankart lesions have been described in the literature. HYPOTHESIS The double-row fixation technique would provide superior reduction and stability of a simulated bony Bankart lesion at time zero in a cadaveric model compared with the single-row technique. STUDY DESIGN Controlled laboratory study. METHODS Testing was performed on 14 matched pairs of glenoids with simulated bony Bankart fractures with a defect width of 25% of the glenoid diameter. Half of the fractures were repaired with a double-row technique, while the contralateral glenoids were repaired with a single-row technique. The quality of fracture reduction was measured with a coordinate measuring machine. To determine the biomechanical stability of the repairs, specimens were preconditioned with 10 sinusoidal cycles between 5 and 25 N at 0.1 Hz and then pulled to failure in the anteromedial direction at a rate of 5 mm/min. Loads at 1 mm and 2 mm of fracture displacement were determined. RESULTS The double-row technique required significantly higher forces to achieve fracture displacements of 1 mm (mean, 60.6 N; range, 39.0-93.3 N; P = .001) and 2 mm (mean, 94.4 N; range, 43.4-151.2 N; P = .004) than the single-row technique (1 mm: mean, 30.2 N; range, 14.0-54.1 N and 2 mm: mean, 63.7 N; range, 26.6-118.8 N). Significantly reduced fracture displacement was seen after double-row repair for both the unloaded condition (mean, 1.1 mm; range, 0.3-2.4 mm; P = .005) and in response to a 10-N anterior force applied to the defect (mean, 1.6 mm; range, 0.5-2.7 mm; P = .001) compared with single-row repair (unloaded: mean, 2.1 mm; range, 1.3-3.4 mm and loaded: mean, 3.4 mm; range, 1.9-4.7 mm). CONCLUSION The double-row fixation technique resulted in improved fracture reduction and superior stability at time zero in this cadaveric model. CLINICAL RELEVANCE This information may influence the surgical technique used to treat large osseous Bankart fractures and the postoperative rehabilitation protocols implemented when such repair techniques are used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arthroscopic Anterior Shoulder Stabilization With Incorporation of a Comminuted Bony Bankart Lesion

Bony Bankart lesions are a common finding in patients with anterior glenohumeral dislocation. Although there are no defined guidelines, small bony Bankart fractures are typically treated arthroscopically with suture anchors. The 2 main techniques used are double- and single-row suture anchor stabilization, with debate over superiority. Biomechanical studies have shown improved reduction and sta...

متن کامل

Arthroscopic Bony Bankart Repair

Arthroscopic stabilization has proven an effective technique in the treatment of anterior shoulder instability due to soft tissue labrum/ligamentous (i.e. Bankart) injury. However, this procedure has not proven as reliable in patients with glenoid rim fractures that have either been neglected or unrecognized, and gone on to resorb. Consequently, there has been a growing emphasis on the importan...

متن کامل

Arthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report

We present a case of arthroscopic fixation for bony Bankart lesion using a double-threaded cannulated screw. A 39-year-old man sustained a left shoulder injury from a motorcycle accident. Radiographs showed bony Bankart lesion and CT revealed 40% defect of glenoid articular surface. Arthroscopic fixation was performed using double-threaded cannulated screw after the bony fragment was reduced by...

متن کامل

Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review

Background The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. Purpose To present a review of...

متن کامل

The "bony Bankart bridge" procedure: a new arthroscopic technique for reduction and internal fixation of a bony Bankart lesion.

Arthroscopic treatment of bony Bankart lesions can be challenging. We present a new easy and reproducible technique for arthroscopic reduction and suture anchor fixation of bony Bankart fragments. A suture anchor is placed medially to the fracture on the glenoid neck, and its sutures are passed around the bony fragment through the soft tissue including the inferior glenohumeral ligament complex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014