Lengthening of a single-loop tibialis tendon graft construct after cyclic loading: a study using Roentgen stereophotogrammetric analysis.
نویسندگان
چکیده
Although single-loop tibialis tendon allografts have increased in popularity owing to their many advantages over patellar tendon and double-loop hamstring tendon autografts, some percentage of the patient population do not have clinically stable knees following anterior cruciate ligament reconstruction with single-loop tibialis tendon allografts. Therefore, it would be advantageous to determine the causes of increased anterior laxity which ultimately must be traced to lengthening of the graft construct. One objective of this study was to demonstrate the feasibility of using Roentgen stereophotogrammetric analysis (RSA) to determine the causes of lengthening of a single-loop graft construct subjected to cyclic loading. A second objective was to determine which cause(s) contributes most to an increase in length of this graft construct. Radio-opaque markers were inserted into ten grafts to measure the lengthening at the sites of the tibial and femoral fixations and between the sites of fixation. Each graft was passed through a tibial tunnel in a calf tibia, looped around a rigid cross-pin, and fixed to the tibia with a Washerloc fixation device. The grafts were cyclically loaded for 225,000 cycles from 20 to 170 N. Prior to and at intervals during the cyclic loading, simultaneous radiographs were taken. RSA was used to determine the three-dimensional coordinates of the markers from which the lengthening at the sites of fixation and between the sites of fixation was computed at each interval. The sites of the femoral and tibial fixations were the largest contributors to the increase in length of the graft construct, with maximum average values of 0.68 and 0.55 mm, respectively, after 225,000 cycles. The graft substance between the sites of fixation contributed least to lengthening of the graft, with a maximum average value of 0.31 mm. Ninety percent of the maximum average values occurred before 100,000 cycles of loading for the largest contributors. RSA proved to be a useful method for measuring lengthening due to all three causes. Lengthening of the graft construct at the sites of both fixations is sufficiently large that the combined contributions may manifest as a clinically important increase in anterior laxity.
منابع مشابه
Migration of radio-opaque markers injected into tendon grafts: a study using roentgen stereophotogrammetric analysis (RSA).
An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct either at the sites of fixation and/or between the sites of fixation (i.e., graft substance). Roentgen stereophotogrammetric analysis (RSA), which requires that radio-opaque markers be attached to the graft, has been shown to be a useful technique in...
متن کاملLengthening of double-looped tendon graft constructs in three regions after cyclic loading: a study using Roentgen stereophotogrammetric analysis.
Lengthening of a double-looped tendon graft construct used to reconstruct the anterior cruciate ligament (ACL) can result in an increase in anterior knee laxity and affect the stability of the reconstructed knee. Three possible regions where lengthening of the construct can occur are (1) the region of the tibial fixation, (2) the region of the femoral fixation, and (3) the region of the graft b...
متن کاملHow cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: a study using roentgen stereophotogrammetric analysis (RSA).
An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct in either the regions of fixation and/or the region of the graft substance between the fixations. RSA could be a useful technique to determine lengthening in these regions if a method can be devised for attaching radio-opaque markers to soft tissue g...
متن کاملRoentgen stereophotogrammetric analysis methods for determining ten causes of lengthening of a soft-tissue anterior cruciate ligament graft construct.
There are many causes of lengthening of an anterior cruciate ligament soft-tissue graft construct (i.e., graft+fixation devices+bone), which can lead to an increase in anterior laxity. These causes can be due to plastic deformation andor an increase in elastic deformation. The purposes of this in vitro study were (1) to develop the methods to quantify eight causes (four elastic and four plastic...
متن کاملDoes graft construct lengthening at the fixations cause an increase in anterior laxity following anterior cruciate ligament reconstruction in vivo?
A millimeter-for-millimeter relation between an increase in length of an anterior cruciate ligament graft construct and an increase in anterior laxity has been demonstrated in multiple in vitro studies. Based on this relation, a 3 mm increase in length of the graft construct following surgery could manifest as a 3 mm increase in anterior laxity in vivo, which is considered clinically unstable. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanical engineering
دوره 128 3 شماره
صفحات -
تاریخ انتشار 2006