The single particle tracking system

نویسندگان

  • Ai-Tang Chang
  • Yi-Ren Chang
  • Sien Chi
  • Long Hsu
  • Kishan Dholakia
  • Gabriel C. Spalding
چکیده

In an optical tweezers system, the force measurement with a resolution less than pico-Newton can be achieved by precise measurement and analysis of the trapped particle trajectory. Typically, this single particle tracking technique is realized by a quadrant position sensor which detects the scattering lights of the trapping laser beam from the trapped particle. However, as the radius of the trapped particle is larger than the wavelength of the trapped laser, the scattering pattern becomes complicated, and it limits the tracking region and the signal sensitivity on the trapped particle. To solve this issue, an extra probing laser with optimized focal offset according to the trapping laser is applied to improve the flexibility and performance of our particle tracking system for each particle size. A rule of thumb between the optimized focal offsets and particle size is also concluded from the experimental results and theoretical simulations. Keyword: photonic force microscopy; quadrant-photo detector; particle tracking. Introduction The force measurement, within a microscopic observation region, is an important issue in many fields such as biophysics, condensed material physics, and hydrodynamics of micro-sized system. Since 1996, E. H. f. Stelzer developed the photonic force microscope (PFM). PFM has become a powerful tool to analysis and investigate the mechanical forces of microstructures in microscopy system. A typical PFM setup is combined two parts ⎯⎯⎯ a probe particle which is a micro-sized polystyrene bead trapped by an optical tweezers and a position sensor system to measure the displacement of the trapping particle with respect to the trapping laser focus. To take a biomechanical application as an example, a probe particle is tethered to the cell or molecule under study. Around the trapping laser focus, the optical tweezers provides a restoring force on the probe particle to the trapping center and the force is linear in the probe particle displacement. Consequently, the measurement of an external force is reduced to measuring the position of the probe particle in the calibrated optical tweezers system around the trapped center. Optical Trapping and Optical Micromanipulation VII, edited by Kishan Dholakia, Gabriel C. Spalding, Proc. of SPIE Vol. 7762, 77622Q · © 2010 SPIE · CCC code: 0277-786X/10/$18 · doi: 10.1117/12.860934 Proc. of SPIE Vol. 7762 77622Q-1 Downloaded From: http://proceedings.spiedigitallibrary.org/ on 04/25/2014 Terms of Use: http://spiedl.org/terms As illustrated in Fig. 1, the schematic setup of the position sensor system is used to measure the probe particle position. The focus of the trap laser, converged by the objective, captures the probe particle. The condenser (CL) collects the forward scattering light from the trap laser on the quadrant-photo detector (QPD1), and the backward scattering light, collected by the objective, illuminates on the other quadrant-photo detector (QPD2). When the trapped particle slightly moves from the trapping center, the scattering light also changes on the quadrant-photo detectors QPD1 and QPD2. The three dimensional position of the probe particle can be measured through the scattering light variation. A quadrant-photo detector compares four photo sensors. Along the x direction, the displacement of the particle b = (bx, by, bz) can be measurement from the signal Sx = [(B+D) (A+C)] / [A′+B′+C′+D′] in Fig. 1 (d). For the same reason, the signal Sy = [(A+B) (C+D)] / [A′+B′+C′+D′] is measured for the displacement of the particle along the y direction and the signal Sz = (A + B + C + D) / [A′+B′+C′+D′] is measured for the displacement along the z direction. The normalized factor [A′+B′+C′+D′] is defined the signal measured by the quadrant-photo detector when the particle is captured at the trapping center. Fig. 1.The schematic setup of the position sensor system However, the scattering pattern is complicated on the position sensor, when the radius of the probe particle is larger than the laser wavelength. The linear range of the displacement signal is reduced. Otherwise, the three dimensional signals are not independent on each direction. In other words, the signal Sx not only varies with the particle movement along the x direction but also changes with the particle movement along another direction. To solve this problem, an extra laser source, rather than the trap laser, is used to detect the movement of the trapped particle. We call this optical mechanism as the single particle tracking system. To adjust the focal offset of the probe laser, the linear range and the sensitivity of the quadrant-photo detector signals will be enhanced effectively and the signal coupling effect is also reduced. The relationship between optimized focal offset of the probe laser and the Proc. of SPIE Vol. 7762 77622Q-2 Downloaded From: http://proceedings.spiedigitallibrary.org/ on 04/25/2014 Terms of Use: http://spiedl.org/terms tracked particle size is obtained experimentally and theoretically 3, 4 and . Setup Fig. 2 shows the schematic representation of the optical setup. The trap laser source is Nd:YAG solid state laser emitting a laser beam at the wavelength of 800 nm in water. A beam expander (Lens L1 and tube lens TL) makes the trap laser to overfill the entrance pupil of the objective (Obj.) in order to optimize the optical tweezers efficient. A 100X oil-immersed objective with a numerical aperture of 1.25 serves as the focal lens. The trapping laser beam, after the objective, is focused at the objective optical axis to trap a micro-sized spherical particle. We use a piezo-translation stage (PZT), controlled by a computer, as the sample holder to move the sample precisely. The Minimum step of this stage is 1.22 nm. As for the single particle tracking system, a helium-neon (He-Ne) laser, with the wavelength of 475.8 nm in water, is used as the probe laser in our experimental setup. A lens set (L4 and L5) also makes the probe laser beam to overfill the entrance pupil of the objective. The lens L4 is movable to control the focal position of the probe laser beam on the objective optical axis. A condenser (CL) collects the forward scattering light of the probe laser from the trapped particle, directing the light on the quadrant photo-detector (QPD1). The condenser with the numerical aperture of 0.65 is co-focal with the objective and QPD1 is placed at the backward focal plane of the condenser. Additionally, the backward scattering light, sticking on the other quadrant photo-detector (QPD2) from the beam splitter (BS), is collected by the objective. QPD2 is placed near the image plane of the objective and lens L3. To reduce the signal noises of the quadrant photo-detectors, the filters are placed before these two detectors to prevent from the incidence of the trapping laser beam. A CCD camera is used to monitor the image of the sample. Proc. of SPIE Vol. 7762 77622Q-3 Downloaded From: http://proceedings.spiedigitallibrary.org/ on 04/25/2014 Terms of Use: http://spiedl.org/terms Fig. 2 shows the optical setup of the single particle tracking system. (DM: dichoric mirror; TL: tube lens; CL: condenser; BS: beam splitter; QPD: quadrant-photo detector) Method To accurately control the focal position of the probe laser, the piezo-translation stage is used to be a sample holder. Micro-sized particles, with different radiuses (245 nm (0.515λ), 500 nm (1.05λ), 1500 nm (3.15λ), 2200 nm (4.62λ) and 3100 nm (6.52λ)), are fixed in an agarose gel (1% agarose aqueous) on the piezo-translation stage. These particles are moved according to the immobile focal position of the probe laser. There are two remarkable features in this experimental method. At first, to change the probe laser focal point along the objective optical axis, the adjustment of the optical mechanism brings some errors with a slight lateral displacement of the focal point from the optical axis. In place of the adjustment of the optical mechanism with the errors, the piezo-translation stage provides the precise movement to achieve the stable experiment platform. Further, the spherical particles is fixed in the agarose gel rather than be adhered on a microscope glass slide. The agarose gel is made by mixing 1% agarose powders with 99% deionized water. The refraction index of the gel is very close to the deionized water. Thus, the gel with a fixed spherical particle is very similar to the conditions of the spherical particle which is trapped by optical tweezers in the water, and the particle does not randomly move due to Brownian motion. As illustrated in Fig. 3(a), the spherical particle, fixed in the gel on the piezo-translation stage, is moved step by step at the x-y plane perpendicular the optical axis (z axis). The displacement signals of Proc. of SPIE Vol. 7762 77622Q-4 Downloaded From: http://proceedings.spiedigitallibrary.org/ on 04/25/2014 Terms of Use: http://spiedl.org/terms the quadrant-photo detectors, used to detect the forward and backward scattering light of the probe laser from the particle, are recorded for each step. The distance of each step is 24.4 nm, and the total movement area of the particle is 2440 X 2440 nm (∼5λ X 5λ). After the signals recording finished at one layer, the particle is moved to next layer along the optical axis to execute the signal recording process continuously. According to each particle size, the total displacement range and each step of the piezo-translation stage, along the optical axis, are also different. Results The spherical particle is a symmetric shape and a uniform material. When the particle is moved across the optical axis on the x-y plane, the signals, detected by the quadrant-photon detectors, are also symmetric profiles. The symmetry property of the quadrant-photon detector signals (Sx, Sy, and Sz) can be shown as: ); , ( ) , ( ) , ( y x x y x x y x x b b S b b S b b S − = − − = (1) ); , ( ) , ( ) , ( y x y y x y y x y b b S b b S b b S − = − − = (2) ). , ( ) , ( ) , ( y x z y x z y x z b b S b b S b b S − = − = (3) On the x-y plane, the symmetric centers of the quadrant-photon detector signals are detected when the particle is right at the optical axis. Thus, we can define this symmetric center signal as the origin point, and find out the origin point in each x-y layer. As illustrated in the Fig. 3, the signals (Sx and Sy), detected by QPD1 (forward scattering light), are the function of the particle displacements (bx and by) at two different layers (bz1 and bz2). The radius of the spherical particle is 0.5 μm (1.05λ). The contour maps (∼3λ X 3λ) are cut off the section of the raw experiment date (5λ X 5λ), and the origin point is the center point of the each contour map. Fig. 3. The signals (Sx and Sy), detected by QPD1 (forward scattering light), are the function of the particle Proc. of SPIE Vol. 7762 77622Q-5 Downloaded From: http://proceedings.spiedigitallibrary.org/ on 04/25/2014 Terms of Use: http://spiedl.org/terms displacements (bx and by) at two different layers (bz1 and bz2). In addition, the particle, on the optical axis, moved upward the distance bz according to the fixed probe laser focus is equal to downward the same distance bz of the probe laser focus from the immovable particle. The focal displacement of the probe laser Zp can be defined as the focal position according to the altitude of the tracked particle along the optical axis (Zp = -bz). The quadrant-photon detector signals, along the optical axis, can be obtained from each x-y layer. As illustrated in Fig. 4, the quadrant-photon signals Sx and Sz, along the optical axis, are the function of the particle displacement bx and the displacement of the probe laser focus Zp. Fig. 4. The quadrant-photon signals Sx and Sz, along the optical axis, are the function of the particle displacement bx and the probe laser focal displacement Zp. From this experimental result, an optical tweezers with a suitable particle tracking system can be built. The suitable displacement of the probe laser focus is about 2λ (∼950 nm), when the particle, with the radius 0.5 μm, is tracked in the optical tweezers system with forward scattering configuration. The trapping laser focus is regulated at the origin point in Fig. 4, since the particle is usually trapped around the focal point of the trapping laser. Therefore, the coupling influence of the quadrant-photo detector signals will be effective reduction. Otherwise, the different size spherical particles, with radius 245 nm (0.515λ), 500 nm (1.05λ), 1500 nm (3.15λ), 2200 nm (4.62λ), and 3100 nm (6.52λ), have been measured by the configurations of the forward and backward scattering in our experiment. According to the experimental results, all the linear relationships, between the signals of the quadrant-photo detector and the particle displacements, can be found when the probe laser focus is located at the optimized position. Proc. of SPIE Vol. 7762 77622Q-6 Downloaded From: http://proceedings.spiedigitallibrary.org/ on 04/25/2014 Terms of Use: http://spiedl.org/terms To track a single particle position by using the quadrant-photon detector, the most important parameters are the signal sensitivity and the detectable tracking range of the particle displacement. Thus, these two parameters determine the optimized focal position of the probe laser. Considering the particle trapped around the trapping beam focus, the signal sensitivity of the particle displacement can be defined as: ) 0 , 0 , 0 ( ) , , ( ) ( = ∂ ∂ ∂ ∂ ∂ ∂ = b z z

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pareto design of fuzzy tracking control based on the particle swarm optimization algorithm for a walking robot in the lateral plane on slope

Many researchers have controlled and analyzed biped robots that walk in the sagittal plane. Nevertheless, walking robots require the capability to walk merely laterally, when they are faced with the obstacles such as a wall. In walking robot field, both nonlinearity of the dynamic equations and also having a tracking system cause an effective control has to be utilized to address these problems...

متن کامل

Potentials of Evolving Linear Models in Tracking Control Design for Nonlinear Variable Structure Systems

Evolving models have found applications in many real world systems. In this paper, potentials of the Evolving Linear Models (ELMs) in tracking control design for nonlinear variable structure systems are introduced. At first, an ELM is introduced as a dynamic single input, single output (SISO) linear model whose parameters as well as dynamic orders of input and output signals can change through ...

متن کامل

Tracking Football Player Movement From a Single Moving Camera Using Particle Filters

This paper deals with the problem of tracking football players in a football match using data from a single moving camera. Tracking footballers from a single video source is di cult: not only do the football players occlude each other, but they frequently enter and leave the camera's eld of view, making initialisation and destruction of a player's tracking a di cult task. The system presented h...

متن کامل

An Efficient Target Tracking Algorithm Based on Particle Filter and Genetic Algorithm

In this paper, we propose an efficient hybrid Particle Filter (PF) algorithm for video tracking by employing a genetic algorithm to solve the sample impoverishment problem. In the presented method, the object to be tracked is selected by a rectangular window inside which a few numbers of particles are scattered. The particles’ weights are calculated based on the similarity between feature vecto...

متن کامل

A New Modified Particle Filter With Application in Target Tracking

The particle filter (PF) is a novel technique that has sufficiently good estimation results for the nonlinear/non-Gaussian systems. However, PF is inconsistent that caused mainly by loss of particle diversity in resampling step and unknown a priori knowledge of the noise statistics. This paper introduces a new modified particle filter called adaptive unscented particle filter (AUPF) to overcome th...

متن کامل

Energy Modeling and Simulation including particle technologies within Single and Double Pass Solar Air Heaters

In order to obtain the best performance of the solar air heaters, it is necessary to find optimum performance conditions. The aim of this research paper is to achieve optimum conditions, by comparing single and double pass solar air heaters. Also, a brief review study of various related research works of all scenarios for a single and double pass and packed bed (including particle technologies)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010