Frequency modulation detection in cochlear implant subjects.

نویسندگان

  • Hongbin Chen
  • Fan-Gang Zeng
چکیده

Frequency modulation (FM) detection was investigated in acoustic and electric hearing to characterize cochlear-implant subjects' ability to detect dynamic frequency changes and to assess the relative contributions of temporal and spectral cues to frequency processing. Difference limens were measured for frequency upward sweeps, downward sweeps, and sinusoidal FM as a function of standard frequency and modulation rate. In electric hearing, factors including electrode position and stimulation level were also studied. Electric hearing data showed that the difference limen increased monotonically as a function of standard frequency regardless of the modulation type, the modulation rate, the electrode position, and the stimulation level. In contrast, acoustic hearing data showed that the difference limen was nearly a constant as a function of standard frequency. This difference was interpreted to mean that temporal cues are used only at low standard frequencies and at low modulation rates. At higher standard frequencies and modulation rates, the reliance on the place cue is increased, accounting for the better performance in acoustic hearing than for electric hearing with single-electrode stimulation. The present data suggest a speech processing strategy that encodes slow frequency changes using lower stimulation rates than those typically employed by contemporary cochlear-implant speech processors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-pass filtering in amplitude modulation detection associated with vowel and consonant identification in subjects with cochlear implants.

Temporal auditory analysis of acoustic events in various frequency channels is influenced by the ability to detect amplitude modulations which for normal hearing involves low-pass filtering with a cutoff frequency around 100 Hz and a rejection slope of about 10 dB per decade. These characteristics were established in previous studies measuring modulation transfer functions. For cochlear implant...

متن کامل

Spectrotemporal Modulation Detection and Speech Perception by Cochlear Implant Users

Spectrotemporal modulation (STM) detection performance was examined for cochlear implant (CI) users. The test involved discriminating between an unmodulated steady noise and a modulated stimulus. The modulated stimulus presents frequency modulation patterns that change in frequency over time. In order to examine STM detection performance for different modulation conditions, two different tempor...

متن کامل

Comment on "Temporal modulation transfer functions in patients

Shannon [I. Acoust. Soc. Am. 91, 2156-2164 (1992) ] reports a strong decrease of modulation detection thresholds with cochlear implant patients for an increase of the stimulus level. His conclusion that this result differs from the findings for acoustical stimulation in normalhearing subjects needs some clarification. His statement about acoustic stimulation is based on modulation detection mea...

متن کامل

The Effect of Interaural Frequency Mismatch on Correlation Change Detection in Bilateral Cochlear-Implant Users

The Effect of Interaural Frequency Mismatch on Correlation Change Detection in Bilateral Cochlear-Implant Users Matthew Goupell University of Maryland College Park Background The insertion depth of a cochlear implant (CI) may differ across the ears in the case of bilateral implantation. This will cause an interaural frequency mismatch of electrical stimulation that may affect binaural processin...

متن کامل

Temporal modulation transfer functions in patients with cochlear implants.

Thresholds for the detection of amplitude modulation were measured in cochlear implant patients as a function of modulation frequency. Three types of threshold measures were taken: detection of amplitude modulation, detection of low-frequency sinusoidal current waveforms, and detection of beats in two-tone complexes. The temporal modulation transfer function (TMTF), defined as the plot of modul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 116 4 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2004