Performance of chemically modified plastic blood collection tubes.

نویسندگان

  • Raffick A R Bowen
  • Samuel C Kim
  • Annie Sattayapiwat
  • Vanessa Austria-Esguerra
  • Richard N Zare
چکیده

OBJECTIVE The objective of this study was to compare newly-modified and aged chemoPET tubes, which contain no problematic surfactants, with commercially available serum blood collection tubes (BCTs) for use in analysis of cortisol, total triiodothyronine (TT3), total thyroxine (TT4), and routine clinical chemistry analytes in serum from apparently healthy volunteers and pooled quality control (QC) specimens. MATERIALS AND METHODS Blood specimens collected from 60 apparently healthy volunteers (18 males, 42 females) and pooled QC specimens poured into seven different BCTs were analyzed by a trained phlebotomist. Cortisol, TT3, and TT4 levels were measured on an Immulite 1000 instrument and routine chemistry tests were analyzed on a Siemens RxL instrument. The significance of differences between chemoPET and other BCT types compared to glass tubes were assessed by Student's paired t-test or repeated measures ANOVA or their non-parametric equivalents. The BCT-related biases (deviation from glass tubes) in analyte concentrations were compared with the current desirable allowable bias, derived from biological variation. Serum analyte concentrations in the different BCTs that exceeded their respective significant change limits were considered clinically significant. RESULTS No statistically and/or clinically significant differences were noted in the analyte concentrations from serum specimens and pooled QC material when our newly modified and aged chemoPET tubes were compared to glass and other BCTs. CONCLUSIONS The chemoPET tubes described here may be a suitable alternative to serum BCTs that contain problematic surfactants known to interfere with some clinical assays on the Immulite 1000 and RxL instruments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Blood Collection Systems on Coagulation Tests

OBJECTIVE Coagulation tests are influenced by pre-analytic conditions such as blood collection systems. Change of glass collection tubes with plastic ones will cause alteration of the test results. The aim of this study was to compare three plastic blood collection tubes with a standard glass blood collection tube and each plastic collection tube with the other two for possible additional tube-...

متن کامل

Performance Comparison of Two Different Branded Blood Collection Tubes Used in Biochemistry Laboratory

Background and Aims: Blood collection tubes (BCT) with gel separators are diagnostic devices that can affect all laboratory processes. In this study, the aim was to compare the performance of a new brand of BCT with the sample tubes that are well-known and widely used in the market. Materials and Methods: Blood samples were taken from 50 healthy volunteers to two brands of BCTs (KWS and BD Vac...

متن کامل

Carbohydrate-deficient transferrin is not affected by serum separators.

We studied the possible effects on serum carbohydrate-deficient transferrin (CDT) determination by a CDTect (Pharmacia) method of serum isolation in four different types of blood-collection tubes, namely: (1) glass tubes (glass Vacutainer tubes with no additive); (2) S-Monovette Neutral tubes (plastic tubes with no additive); (3) S-Monovette Serum tubes (plastic tubes with kaolin-coated plastic...

متن کامل

Evidence for endotoxin contamination in plastic Na+-heparin blood collection tube lots.

BACKGROUND Biomarker assays are often conducted on whole blood samples in the course of drug development studies. Because bacterial lipopolysaccharide (LPS) (endotoxin) contamination is known to cause spontaneous cytokine production by monocytes, contamination of blood collection tubes may interfere with biomarker assay results. METHODS Whole blood from healthy donors was collected into plast...

متن کامل

Effect of blood collection tubes on total triiodothyronine and other laboratory assays.

BACKGROUND Increased total triiodothyronine (TT(3)) assay results in apparently euthyroid patients triggered an investigation of the effect of blood collection tubes on serum TT(3) and other laboratory assays. METHODS We examined potential assay interference for three types of tubes: plastic Greiner Bio-One Vacuette; glass Becton Dickinson (BD) Vacutainer; and plastic BD Vacutainer SST tubes....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical biochemistry

دوره 49 1-2  شماره 

صفحات  -

تاریخ انتشار 2016