Evaluation of Visibility by Metal Artifact Reduction during Stent-assisted Coil Embolization

نویسندگان

  • Kentaro Mori
  • Tatsuo Amano
  • Masayuki Sato
  • Shuichi Tanoue
  • Hiro Kiyosue
  • Yuji Matsumaru
چکیده

Objective: In cases of stent-assisted coil (SAC) embolization, visualization of stents with cone-beam CT is interfered significantly by the coil mass with streak artifacts. Metal artifact reduction (MAR), which is the algorithm for contrastenhanced cone-beam CT, improves visualization of stents. We analyzed our cases of SAC embolization and report efficacy of MAR. Materials and Methods: We reviewed 37 images of cone-beam CT of 37 aneurysms treated with SAC embolization between 2011 and 2013 in our institution. The 80 kV high-resolution XperCT was performed, and stent images were reconstructed with and without MAR. Neuroradiologists evaluated the following findings using a 3-point scale: stent apposition, stent lumen, and stent strut and anatomy of surrounding small vessels. Results: By applying MAR, scores of findings listed above were improved at least by 1 point in 83.8%, 86.5%, 89.2%, and 29.7% of the cases, respectively, and overall visibility was improved in all of the cases. Improvement of the total score with MAR did not significantly correlate with aneurysm size (r = 0.079). Conclusion: It was significantly valuable to apply MAR for the images after the SAC embolization treatment to observe stent apposition, stent lumen, and stent strut and surrounding vessels. This technique will also provide valuable information for cases of re-treatment or risk analysis for ischemic complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

BACKGROUND AND PURPOSE Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by u...

متن کامل

Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling.

BACKGROUND AND PURPOSE Developments in flat panel angiographic C-arm systems have enabled visualization of both the neurovascular stents and host arteries in great detail, providing complementary spatial information in addition to conventional DSA. However, the visibility of these structures may be impeded by artifacts generated by adjacent radio-attenuating objects. We report on the use of a m...

متن کامل

Risk Factors after Reduction to Single Antiplatelet Therapy for Postoperative Ischemia of Intracranial Stent-assisted Coil Embolization

Objective: There are concerns regarding ischemic events associated with stent-assisted coil embolization. It is important to evaluate the risk factors for delayed thromboembolic events. This study evaluated risk factors after reduction to singleantiplatelet therapy 140–365 days after embolization. Methods: We conducted a retrospective and cross-sectional study of patients who underwent stent-as...

متن کامل

Artifact reduction of different metallic implants in flat detector C-arm CT.

BACKGROUND AND PURPOSE Flat detector CT has been increasingly used as a follow-up examination after endovascular intervention. Metal artifact reduction has been successfully demonstrated in coil mass cases, but only in a small series. We attempted to objectively and subjectively evaluate the feasibility of metal artifact reduction with various metallic objects and coil lengths. MATERIALS AND ...

متن کامل

Endovascular management of bleeding events following robotic pancreaticobiliary surgery.

PURPOSE To describe the utility, safety, and efficacy of endovascular intervention for treating bleeding events after robotic pancreaticobiliary surgery. MATERIALS AND METHODS In this retrospective study, six patients (male/female, 3/3; mean age, 64 years) with histories of robotic pancreaticobiliary resection were referred for endovascular management of delayed postoperative intra-abdominal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017