A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus

نویسندگان

  • Mei Jin
  • Yong-Mei Liang
  • Xiao-Fang Wang
  • Bao-Jing Guo
  • Ke Zheng
  • Yan Gu
  • Zhen-Yu Lyu
چکیده

BACKGROUND Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. METHODS One thousand five hundred and twenty-six patients (537 boys, 989 girls) with PDA from January 1997 to September 2014 underwent descending aortogram and transcatheter occlusion procedure. We retrospectively analyzed data of these patients, including gender, age, weight, size and morphology of PDA, and devices used in transcatheter occlusion, outcomes, and postoperational complications. RESULTS Median age and median weight were 4.0 years (range: 0.3-52.0 years old) and 15.3 kg (range: 4.5-91.0 kg), respectively. Mean ductal diameter, aortic ductal diameter, ductal length, and pulmonary artery pressure were 3.50 ± 2.15 mm, 10.08 ± 2.46 mm, 7.49 ± 3.02 mm, and 30.21 ± 17.28 mmHg, respectively. Morphology of PDA assessed by descending aortogram was of type A in 1428 patients, type B in 6 patients, type C in 79 patients, type D in 4 patients, and type E in 9 patients according to the classification of Krichenko. Of all the 1526 patients, 1497 patients underwent transcatheter PDA closure, among which 1492 were successful. Devices used were Amplatzer duct occluder I (ADO I, 1280, 85.8%), Cook detachable coils (116, 7.8%), ADO II (ADO II, 68, 4.6%), muscular VSD occluder (12, 0.8%), and Amplatzer vascular plug (16, 1.0%). CONCLUSIONS Excellent occlusion rates with low complication rates were achieved with all devices regardless of PDA types. With transcatheter occlusion technique and devices developing, more patients with PDA can be treated with transcatheter closure both safely and efficiently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils.

OBJECTIVE To report initial experience with a new occlusion device for native and residual patent ductus arteriosus. DESIGN Descriptive study of consecutive non-randomised patients undergoing a new method of patent ductus arteriosus closure with detachable coils. SETTING Tertiary centres for paediatric cardiology. PATIENTS 71 consecutive patients, aged 1.2-22 years, with a patent ductus a...

متن کامل

PEDIATRIC AND CONGENITAL HEART DISEASE Original Studies Angiographic and Hemodynamic Predictors for Successful Outcome of Transcatheter Occlusion of Patent Ductus Arteriosus in Infants Less Than 8 Kilograms

Transcatheter occlusion of patent ductus arteriosus (PDA) using Gianturco coils (GCs) has been performed for the past decade. However, little has been written regarding anatomical and hemodynamic predictors for successful occlusion of the PDA in infants. This report is to evaluate the outcome of transcatheter occlusion of PDA in symptomatic infants less than 8 kg and to assess predictors of suc...

متن کامل

Severe thrombocytopenia complicating transcatheter occlusion of a patent ductus arteriosus.

Transcatheter closure of a patent ductus arteriosus (PDA) is a well-established technique that may occasionally be complicated by severe thrombocytopenia. We report herein 6 cases of PDA in which circulating platelet counts were notably reduced within 18-48 hours following the procedure. A number of interventions, including blood-pressure control, protection against hemorrhage, and eradication ...

متن کامل

Successful transcatheter balloon dilatation of coarctation of aorta and coil occlusion of patent ductus arteriosus in a single catheterization procedure.

Simultaneous transcatheter coil occlusion of patent ductus arteriosus and balloon angioplasty of coarctation of aorta is avoided since intimal tearing after angioplasty is believed to increase the risk for dissection of the aorta during catheter manipulation. We report a 14-month-old boy, with weight of 7.6 kg, with aortic coarctation and patent ductus arteriosus with a large left-to-right shun...

متن کامل

Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus

Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 128  شماره 

صفحات  -

تاریخ انتشار 2015