Flow Diverter Therapy With the Pipeline Embolization Device Is Associated With an Elevated Rate of Delayed Fluid-Attenuated Inversion Recovery Lesions.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Flow diversion using the Pipeline Embolization Device is reported as a safe treatment of aneurysms. Complete aneurysm occlusion, however, occurs in a delayed fashion with initial persistent filling of the aneurysm dome. We hypothesized that this transflow across metallic struts may be associated with thromboembolic events. METHODS Forty-one consecutive patients undergoing aneurysm treatment with the Pipeline Embolization Device and a comparison group of 78 Neuroform stent-mediated embolizations were studied. Patients' charts, procedure notes, platelet function, and anticoagulation state were analyzed. Serial magnetic resonance images were assessed for the presence of newly occurring diffusion-weighted imaging and fluid-attenuated inversion recovery (FLAIR) lesions at multiple postprocedure time ranges (average days post procedure [Pipeline Embolization Device/Neuroform]: T1=1, T2=73/107, T3=174, T4=277/335, and T5=409). In addition, diffusion-weighted imaging or FLAIR burden was estimated by lesional diameter summation. RESULTS Pipeline patients were more likely to have new ipsilateral FLAIR lesions at all time points studied (30.6% versus 7.2% of patients at T=2 and 34.5% versus 6.2% at T=4). The mean FLAIR burden was significantly increased for Pipeline patients (10.1 versus 0.7 mm at T=2 and 8.8 versus 1.9 mm at T=4). Overall 34% (14/41) of Pipeline patients experienced a new FLAIR lesion at anytime when compared with 10% (8/78) of Neuroform stent-coil patients. Postprocedural diffusion-weighted imaging did not predict future FLAIR lesions suggesting a nonprocedural cause. CONCLUSIONS The Pipeline Embolization Device is associated with increased rate of de novo FLAIR lesions occurring in a delayed fashion and distinct from perioperative diffusion-weighted imaging lesions. The cause and clinical effect of these lesions are unknown and suggest the need for prudent follow-up and evaluation.
منابع مشابه
Transvenous Aneurysm Sac and Rupture Point Coil Embolization of Direct Carotid Cavernous Fistula after Pipeline Embolization
A delayed aneurysm rupture after flow diverter therapy is a rare but serious complication. Due to the anatomical specificity, a delayed rupture of a carotid cavernous aneurysm may cause a direct carotid cavernous fistula (dCCF). We present a novel therapeutic approach for treatment of dCCF after flow diverter therapy using the Pipeline embolization device (PED). An 86-year-old woman suffered fr...
متن کاملIntravenous C-Arm Conebeam CT Angiography following Long-Term Flow-Diverter Implantation: Technologic Evaluation and Preliminary Results.
BACKGROUND AND PURPOSE A noninvasive investigation with high spatial resolution and without metal artifacts is necessary for long-term imaging follow-up after flow-diverter implantation. We aimed to evaluate the diagnostic value of conebeam CT angiography with intravenous contrast enhancement in the assessment of vascular status following implantation of the Pipeline Embolization Device and to ...
متن کاملAcute thrombus formation on phosphorilcholine surface modified flow diverters
PURPOSE Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). METHODS Elastase-induced aneurysms were created in 40 rabbits and rando...
متن کاملFlow Diverters for Intracranial Aneurysms
Flow diverters (pipeline embolization device, Silk flow diverter, and Surpass flow diverter) have been developed to treat intracranial aneurysms. These endovascular devices are placed within the parent artery rather than the aneurysm sac. They take advantage of altering hemodynamics at the aneurysm/parent vessel interface, resulting in gradual thrombosis of the aneurysm occurring over time. Sub...
متن کاملExtra-aneurysmal flow modification following pipeline embolization device implantation: focus on regional branches, perforators, and the parent vessel.
BACKGROUND AND PURPOSE Flow-diverter technology has proved to be a safe and effective treatment for intracranial aneurysm based on the concept of flow diversion allowing parent artery and collateral preservation and aneurysm healing. We investigated the patency of covered side branches and flow modification within the parent artery following placement of the Pipeline Embolization Device in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2016