Temperature threshold for burn injury: an oximeter safety study.
نویسندگان
چکیده
Pulse oximeters have become essential devices for evaluating and monitoring patient oxygenation. The probe emits a small amount of heat into the skin in the process of signal detection. Regulations set by the Food and Drug Administration currently limit the maximum allowable temperature of an oximeter probe to 41 degrees C. As a result of the prolonged exposure of extremities to these devices, we sought to determine the actual temperature threshold for burn injury in patients. Eighteen patients undergoing surgery for removal of redundant skin (abdominoplasty, breast reduction) consented to the application of a temperature-controlled custom probe with four light-emitting diodes that had temperatures set randomly at the expected threshold for burn injury (42.5 degrees C, 43 degrees C, 43.5 degrees C, and 44 degrees C). The probe was left in place for 8 hours (or less if significant pain was noted). The sites covered by the probes were then checked for signs of injury. On the next day, the redundant skin was removed as a scheduled procedure, and histopathology was performed to detect the extent of burn injury. The study was approved by the local institutional research board. Two patients were excluded because of technical problems with the probe, one of whom had the probe turned off because of pain. The only observed sign of injury was either erythema or a superficial blister that was usually unobservable or slightly red at operation. These subtle signs of a burn were noted in one patient at 43 degrees C, four at 43.5 degrees C, and nine at 44 degrees C. No burns were noted in two patients. Minimal or no signs of injury frequently were noted by histopathology. Pulse oximeter probes are safe up to a temperature of 43 degrees C for at least 8 hours in well-perfused skin. Above that temperature, there is a risk of burn injury. Performing temperature threshold tests in redundant skin that is planned for excision is a potential method for testing the safety of devices or materials.
منابع مشابه
Adapting adult scald safety standards to children.
Scald burns by domestic tap water constitute a painful, potentially debilitating, and sometimes-fatal form of thermal injury. In this setting, the very young and older members of the population are particularly susceptible, owing in part to having thinner skin, which renders them more susceptible to thermal insult. Various codes have set forth a safety standard for maximum delivery temperature ...
متن کاملAn Experimental and Theoretical Study of the Effects of Excess Air Ratio and Waste Gate Opening Pressure Threshold on Nox Emission and Performance in a Turbocharged CNG SI Engine
Turbocharged CNG engines produce high NOx emission due to the fuel type and high combustion temperature. In this research, the effects of lean-burn and waste gate opening pressure threshold on NOx emission are studied theoretically and experimentally at WOT condition as well as 13-mode ECE-R49 test cycle. A code is developed in MATLAB environment for predicting engine NOx and the results are va...
متن کاملCar seat heaters as a potential burn hazard: a clarification.
This letter is submitted to address an error in an article previously published in this journal that has led to confusion concerning the thermal conditions that cause skin burns. The thermal comfort of vehicle occupants has been an issue of concern from the earliest days of automobile design. Many embodiments of vehicular climate control systems have evolved over the years, including the introd...
متن کاملBurns From Hot Wheat Bags: A Public Safety Issue
INTRODUCTION Wheat bags are therapeutic devices that are heated in microwaves and commonly used to provide relief from muscle and joint pain. The Royal Adelaide Hospital Burns Unit has observed a number of patients with significant burn injuries resulting from their use. Despite their dangers, the products come with limited safety information. METHODS Data were collected from the Burns Unit d...
متن کاملshRNA mediated knockdown of Nav1.7 in rat dorsal root ganglion attenuates pain following burn injury
BACKGROUND Abnormal acute pain after burn injury still torments patients severely. In this study, we investigated that one voltage gated sodium channel Nav1.7 plays a vital role in lowering heat pain threshold after burn injury, and the hypothesis that knockdown of Nav1.7 attenuates pain following burn injury. METHODS Sixty eight adult male Sprague-Dawley rats were divided into 4 treatment gr...
متن کاملذخیره در منابع من