TRANSLATIONAL PHYSIOLOGY New method to measure coronary velocity and coronary flow reserve

نویسندگان

  • Z.-D. Zhang
  • M. Svendsen
  • J. S. Choy
  • A. K. Sinha
  • Y. Huo
  • K. Yoshida
  • S. Molloi
  • G. S. Kassab
چکیده

Zhang ZD, Svendsen M, Choy JS, Sinha AK, Huo Y, Yoshida K, Molloi S, Kassab GS. New method to measure coronary velocity and coronary flow reserve. Am J Physiol Heart Circ Physiol 301: H21–H28, 2011. First published May 6, 2011; doi:10.1152/ajpheart.00080.2011.—Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the reproducibility and accuracy of intravascular conductance catheter-based method for measurements of baseline and hyperemic coronary flow velocity (and hence CFR). The absolute coronary blood velocity was determined by measuring the time of transit of a saline injection between two pairs of electrodes (known distance) on a conductance catheter during a routine saline injection without the need for reference flow. In vitro validation was made in the velocity range of 5 to 70 cm/s in reference to the volume collection method. In 10 swine, velocity measurements were compared with those from a flow probe in coronary arteries at different CFR attained by microsphere embolization. In vitro, the mean difference between the proposed method and volume collection was 0.7 1.34 cm/s for steady flow and 0.77 2.22 cm/s for pulsatile flow. The mean difference between duplicate measurements was 0 1.4 cm/s. In in vivo experiments, the flow (product of velocity and lumen cross-sectional area that is also measured by the conductance catheter) was determined in both normal and stenotic vessels and the mean difference between the proposed method and flow probe was 1 12 ml/min (flow ranged from 10 to 130 ml/min). For CFR, the mean difference between the two methods was 0.06 0.28 (range of 1 to 3). Our results demonstrate the reproducibility and accuracy of velocity and CFR measurements with a conductance catheter by use of a standard saline injection. The ability of the combined measurement of coronary lumen area (as previously validated) and current velocity and CFR measurements provides an integrative diagnostic tool for interventional cardiology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New method to measure coronary velocity and coronary flow reserve.

Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the reproducibility and accuracy of intravascular conductance catheter-based method for measurements of baseline and hyperemic coronary flow velocity (and hence CFR). The absolute coronary blood velocity was determined by measuring the time of transit of a saline ...

متن کامل

Translational Physiology TRANSLATIONAL PHYSIOLOGY The diastolic flow velocity-pressure gradient relation and dpv50 to assess the hemodynamic significance of coronary stenoses

Marques, Koen M. J., Machiel J. van Eenige, Hugo J. Spruijt, Nico Westerhof, Jos Twisk, Cees A. Visser, and Frans C. Visser. The diastolic flow velocity-pressure gradient relation and dpv50 to assess the hemodynamic significance of coronary stenoses. Am J Physiol Heart Circ Physiol 291: H2630–H2635, 2006. First published August 18, 2006; doi:10.1152/ajpheart.00030.2006.—To evaluate the hemodyna...

متن کامل

Coronary physiology revisited : practical insights from the cardiac catheterization laboratory.

Various coronary physiological measurements can be made in the cardiac catheterization laboratory using sensor-tipped guidewires; they include the measurement of poststenotic absolute coronary flow reserve, the relative coronary flow reserve, and the pressure-derived fractional flow reserve of the myocardium. Ambiguity regarding abnormal microcirculation has been reduced or eliminated with meas...

متن کامل

Non-invasive measurement of coronary flow reserve in children with Kawasaki disease.

OBJECTIVE To investigate whether transthoracic Doppler echocardiography (TTE) can reliably measure the coronary flow reserve in the left anterior descending coronary artery in children with Kawasaki disease. DESIGN Coronary flow velocity in the distal left anterior descending coronary artery was measured by TTE and was compared with that obtained by intracoronary Doppler guide wire. The ratio...

متن کامل

Functional assessment of coronary stenosis: it does make sense, but why don't I do it more often?

and at 6 months follow-up. As in other studies, there was only moderate correlation between coronary flow velocity reserve and diameter stenosis in lesions of moderate severity and the cut-off of coronary flow velocity reserve was 1·9 for patients with intermediate lesions. There are some known limitations with the use of Doppler coronary flow velocity reserve determinations. To obtain a good s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011