Photographic response to x-ray irradiation. III: Photographic linearization of beam-foil spectra.

نویسندگان

  • C T Chantler
  • J D Silver
  • D D Dietrich
چکیده

In this paper models for the relation of specular density to incident (x-ray) intensity with uncertainties are applied to experimental data, indicating methods for the correction of additional effects. Linearization and error calculations are simplified by double linear interpolation, and the effect of this is quantified. Relative first-order intensities are determined directly. Secondary linearization or calculation for higher-order lines gives correction factors that yield absolute and relative higher-order intensity ratios. The effects of energy and angle on linearization are included. Densitometry uncertainty is estimated and quantified.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis of Silver Nanoparticles from Spent X-Ray Photographic Solution via Chemical Rreduction

Silver metal was recovered primarily from spent X-ray photographic solution using a horizontal tube furnace. The X-Ray Diffraction (XRD) spectroscopy analysis approved almost 95 percent purity of the recovered silver metal. In the next step, the synthesis of silver nanoparticles from the recovered silver metal proceeded by using chemical reduction method. The proposed method uses e...

متن کامل

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

 ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...

متن کامل

Roentgen Ray Intoxication. Iii . T~e Path of a Beam O]~ Hard Rays in Txe Living Organism

l%A~ 45. All roentgenologists are deeply interested in the problems which may be formulated in these few questions: Do the hard x-rays follow a straight and narrow path from the x-ray target through the tissues of the human body? Do these hard x-rays suffer from reflection or refraction and therefore influence tissues outside of this direct path-way? What factor is secondary radiation in the tr...

متن کامل

Medical Physics International

Following the discovery of a “new kind of rays,” to be named by him as x-radiation, and others as Roentgen’s rays, Dr. Roentgen embarked on an intense investigation in a series of innovative experiments to determine its properties and characteristics and how it compared to other known radiations, specifically light and cathode rays. He demonstrated that the radiation produced fluorescence and e...

متن کامل

Shielding simulations for safe use of curtain electron accelerator by MCNP4C

In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 32 13  شماره 

صفحات  -

تاریخ انتشار 1993