Inter-slice Correspondence for 2D Ultrasound-Guided Procedures

نویسندگان

  • Matthew Toews
  • Alexandra J. Golby
  • William M. Wells
چکیده

This paper reports on a new computational methodology, inter-slice correspondence (ISC), for robustly aligning sets of 2D ultrasound (US) slices during image-guided medical procedures. Correspondences are derived from distinctive, local scale-invariant features, which are used in one-to-many matching of US slices in near real-time despite out-of-plane rotation, in addition to global in-plane similarity transforms, occlusion, missing tissue, US plane mirroring, changes in US probe depth settings. Experiments demonstrate that ISC can align manually-acquired US slices without probe tracking information in the context of imageguided neurosurgery, with an accuracy of 1.3mm. A novel reconstructionwithout-calibration application based on ISC is proposed, where 3D US reconstruction results are very similar to those obtained via traditional phantom-based calibration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires t...

متن کامل

Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

PURPOSE Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract the prostate boundaries accurately and efficiently. METHODS In this paper, th...

متن کامل

External radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans

Background: Tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. This method is performed by using 2D and 3D treatment planning. The aim of this study was to compare 2D with 3D plans in breast conserving radiotherapy. Homogeneity of isodose, and lung received dose were compared. Materials and Methods: Twenty patients with br...

متن کامل

Register cardiac fiber orientations from 3D DTI volume to 2D ultrasound image of rat hearts

Two-dimensional (2D) ultrasound or echocardiography is one of the most widely used examinations for the diagnosis of cardiac diseases. However, it only supplies the geometric and structural information of the myocardium. In order to supply more detailed microstructure information of the myocardium, this paper proposes a registration method to map cardiac fiber orientations from three-dimensiona...

متن کامل

A Reliable Real Time Liver Motion Tracking for Application in Magnetic Resonance guided High Intensity Focused Ultrasound Therapy

Introduction High-intensity focused ultrasound has shown potential for ablating liver tumors without the need for surgical procedures [1]. However, the long duration of HIFU scans (~2hrs) and the varying respiratory motion requires that features identified for sonication be tracked in real time during the procedure [2]. The real time tracking would enable a free-breathing MRgFUS treatment and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013