The minimum crystal size needed for a complete diffraction data set
نویسندگان
چکیده
In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 A resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 microm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 microm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.
منابع مشابه
Improved three-dimensional growth of manganese superoxide dismutase crystals on the International Space Station.
Manganese superoxide dismutase was crystallized in microgravity with 35 PCAM experiments (Protein Crystallization Apparatus for Microgravity) on the ISS (International Space Station) from 5 December 2001 to 19 April 2002. Crystals were very large in size and could easily be seen by eye. Crystals with 0.45 x 0.45 mm cross-sections and of up to 3 mm in length were obtained in several drops: an 80...
متن کاملX-ray peak broadening analysis in LaMnO3+δ nano-particles with rhombohedral crystal structure
In this work, structural and magnetic properties of LaMnO3+δ compound prepared by citrate precursor method and annealed in presence of oxygen are investigated. The structural characterization of LaMnO3+δ by X-ray powder diffraction and using X’pert package and Fullprof program is evidence for a rhombohedral structure (R-3c space group) confirmed by FTIR measurement. The magnetic measurements sh...
متن کاملمدیریت ناهنجاری مادرزادی در ایران : طراحی مجموعه حداقل دادههای ملی
Introduction: Congenital anomalies are the leading causes of infant death at birth and during infancy, and are considered as significant and costly health problems. Therefore, a national registry of congenital anomalies is needed to calculate health indexes because collecting and reporting birth anomalies facilitate assessment, and health planning. Consequently, this study aimed to determine t...
متن کاملMinimum data set for electronic health card of schizophrenia
Purpose: Having a clinical information system is a good solution for monitoring medical problems. This system is designed to improve the speed and accuracy of data management. The goal is to replace medical records with a clinical information system to support storing, processing and distributing data in all the sections of a healthcare center. The purpose of this research was to determine ...
متن کاملPerdeuteration, crystallization, data collection and comparison of five neutron diffraction data sets of complexes of human galectin-3C
Galectin-3 is an important protein in molecular signalling events involving carbohydrate recognition, and an understanding of the hydrogen-bonding patterns in the carbohydrate-binding site of its C-terminal domain (galectin-3C) is important for the development of new potent inhibitors. The authors are studying these patterns using neutron crystallography. Here, the production of perdeuterated h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 66 شماره
صفحات -
تاریخ انتشار 2010