Clinical results of stereotactic body frame based fractionated radiation therapy for primary or metastatic thoracic tumors.
نویسندگان
چکیده
The aim of this study was to evaluate the treatment outcomes of stereotactic body radiation therapy for treating primary or metastatic thoracic tumors using a stereotactic body frame. Between January 1998 and February 2004, 101 lesions from 91 patients with thoracic tumors were prospectively reviewed. A dose of 10-12 Gy per fraction was given three to four times over consecutive days to a total dose of 30-48 Gy (median 40 Gy). The overall response rate was 82%, with 20 (22%) complete responses and 55 (60%) partial responses. The one- and two-year local progression free survival rates were 90% and 81%, respectively. The patients who received 48 Gy showed a better local tumor control than those who received less than 48 Gy (Fisher exact test; p = 0.004). No pulmonary complications greater than a RTOG toxicity criteria grade 2 were observed. The experience of stereotactic body frame based radiation therapy appears to be a safe and promising treatment modality for the local management of primary or metastatic lung tumors. The optimal total dose, fractionation schedule and treatment volume need to be determined after a further follow-up of these results.
منابع مشابه
A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates
Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...
متن کاملSuccessful treatment of a T4 lung tumor with vertebral body invasion using fiducial markers in the thoracic spine for image-guided radiation therapy: A case report
INTRODUCTION Paravertebral and paraspinal tumors pose a significant challenge in radiation therapy because of the radiation sensitivity of the spinal cord and the need for maximum treatment accuracy. Implantation of fiducial markers into vertebral bodies has been described as a method of increasing the accuracy of radiation treatment for single-dose stereotactic radiosurgery for spinal and para...
متن کاملRole of Radiation Therapy in the Management of Renal Cell Cancer
Renal cell carcinoma (RCC) is traditionally considered to be radioresistant; therefore, conventional radiotherapy (RT) fraction sizes of 1.8 to 2 Gy are thought to have little role in the management of primary RCC, especially for curative disease. In the setting of metastatic RCC, conventionally fractionated RT has been an effective palliative treatment in 50% of patients. Recent technological ...
متن کاملFractionated Stereotactic Gamma Knife Radiosurgery for Large Brain Metastases: A Retrospective, Single Center Study
PURPOSE Stereotactic radiosurgery (SRS) is widely used for brain metastases but has been relatively contraindicated for large lesions (>3 cm). In the present study, we analyzed the efficacy and toxicity of hypofractionated Gamma Knife radiosurgery to treat metastatic brain tumors for which surgical resection were not considered as the primary treatment option. METHODS AND MATERIALS Thirty-six...
متن کاملRadiobiological mechanisms of stereotactic body radiation therapy and stereotactic radiation surgery
Despite the increasing use of stereotactic body radiation therapy (SBRT) and stereotactic radiation surgery (SRS) in recent years, the biological base of these high-dose hypo-fractionated radiotherapy modalities has been elusive. Given that most human tumors contain radioresistant hypoxic tumor cells, the radiobiological principles for the conventional multiple-fractionated radiotherapy cannot ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta oncologica
دوره 45 8 شماره
صفحات -
تاریخ انتشار 2006