Parametric images of myocardial viability using a single 15O-H2O PET/CT scan.
نویسندگان
چکیده
UNLABELLED Perfusable tissue index (PTI) is a marker of myocardial viability and requires acquisition of transmission, (15)O-CO, and (15)O-H(2)O scans. The aim of this study was to generate parametric PTI images from a (15)O-H(2)O PET/CT scan without an additional (15)O-CO scan. METHODS Data from 20 patients undergoing both (15)O-H(2)O and (15)O-CO scans were used, assessing correlation between PTI based on (15)O-CO (PTI(CO)) and on fitted blood volume fractions (PTI(Vb)). In addition, parametric PTI(Vb) images of 10 patients undergoing (15)O-H(2)O PET/CT scans were generated using basis-function methods and compared with PTI(Vb) obtained using nonlinear regression. Simulations were performed to study the effects of noise on PTI(Vb). RESULTS Correlation between PTI(CO) and PTI(Vb) was high (r(2) = 0.73). Parametric PTI(Vb) correlated well with PTI(Vb) obtained using nonlinear regression (r(2) = 0.91). Simulations showed low sensitivity to noise (coefficient of variation < 10% at 20% noise). CONCLUSION Parametric PTI images can be generated from a single (15)O-H(2)O PET/CT scan.
منابع مشابه
Parametric images of myocardial viability using a single [O]H2O PET/CT scan
Perfusable tissue index (PTI) is a marker of myocardial viability and requires acquisition of transmission, [O]CO and [O]H2O scans. The aim of this study was to generate parametric PTI images from a [O]H2O PET/CT scan without an additional [O]CO scan. Methods: Data from 20 patients undergoing both [O]H2O and [ O]CO scans were used, assessing correlation between PTI based on [O]CO (PTICO) and on...
متن کاملParametric imaging of myocardial blood flow with 15O-water and PET using the basis function method.
UNLABELLED Regional myocardial blood flow (MBF) can be measured with 15O-water and PET using the 1-tissue-compartment model with perfusable tissue fraction, which provides an MBF value that is free from the partial-volume effect. Studies with 15O-water have several advantages, such as the ability to repeat a scan. However, because of the short scanning time and the small distribution volume of ...
متن کاملCalculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET
BACKGROUND Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from stand...
متن کاملQuantitative myocardial blood flow imaging with integrated time-of-flight PET-MR
BACKGROUND The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mea...
متن کاملSystemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan
Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 52 5 شماره
صفحات -
تاریخ انتشار 2011