Atherosclerotic plaque characterization by 0.5-mm-slice multislice computed tomographic imaging.
نویسندگان
چکیده
BACKGROUND It has been proposed that 0.5-mm-slice multislice computed tomography (MSCT) is a noninvasive tool for the detection of atherosclerotic plaque, but the validity of such an assessment has not been demonstrated by an invasive investigation. The present study was performed to compare the 0.5-mm-slice MSCT density of plaques with intravascular ultrasound (IVUS) findings. METHODS AND RESULTS Atherosclerotic plaques were characterized in 37 consecutive patients undergoing percutaneous interventions. Based on the IVUS echogenecity, the plaques were classified as soft (n=18), fibrous (n=40) or calcified (n=40). In these 98 plaques, 0.5-mm-slice MSCT plaque density was calculated in 443 regions-of-interest, including 331 lesional foci and 112 luminal cross-sections, and represented as Hounsfield units (HU). MSCT density of the 3 types of plaque was 11+/-12 HU, 78+/-21 HU, and 516 +/-198 HU respectively. Computed tomography density of the (contrast-filled) lumen was 258+/-43 HU. There were statistically highly significant differences in the densitometric characteristics among the 4 groups (soft, fibrous, calcified plaque and lumen) by nonparametric Kruskal-Wallis test (p<0.0001). CONCLUSIONS The IVUS-based coronary plaque configuration can be accurately identified by 0.5-mm slice MSCT. Noninvasive assessment of plaque characterization will ensure emphasis on the vessel wall beyond the vascular lumen.
منابع مشابه
Sixty-four-row multislice computed tomographic angiography in the diagnosis and characterization of intracranial aneurysms: comparison with 3D rotational angiography.
BACKGROUND Sixty-four-row multislice computed tomographic angiography (CTA) has great potential for use in vascular studies. The aim of our study was to compare 64-slice CTA with three-dimensional rotational angiography (3DRA) in the detection and characterization of intracranial aneurysms with special attention to smaller (<3-mm) aneurysms. METHODS In a prospective study, a total of 133 pati...
متن کاملNew imaging techniques for diagnosing coronary artery disease.
New tomographic cardiovascular imaging tests, such as intravascular ultrasonography (IVUS), coronary computed tomography (CT) angiography and magnetic resonance imaging (MRI), can be used to assess atherosclerotic plaques for the characterization and early staging of coronary artery disease (CAD). Although IVUS images have very high resolution capable of revealing very early preclinical CAD, it...
متن کاملIn vivo 16-slice, multidetector-row computed tomography for the assessment of experimental atherosclerosis: comparison with magnetic resonance imaging and histopathology.
BACKGROUND Noninvasive imaging can detect early atherosclerotic disease. Magnetic resonance imaging (MRI), because of its excellent spatial resolution, is already established as a tool for plaque characterization. Sixteen-slice, multidetector-row computed tomography (MDCT) was recently introduced into the field of cardiac imaging, with promising results for noninvasive angiography. We compared ...
متن کاملRelationship between tissue characterization with 40 MHz intravascular ultrasound imaging and 64-slice computed tomography.
BACKGROUND Identification of coronary plaque composition is important for selecting the treatment strategy, and 64-slice computed tomography (CT) is a noninvasive method of characterizing atherosclerotic plaques. However, the correlation between plaque characteristics detected by CT and intravascular ultrasound (IVUS) is not clear. A 40 MHz IVUS imaging system (iMap-IVUS) has recently been deve...
متن کاملNon-invasive evaluation of atherosclerosis with contrast enhanced 16 slice spiral computed tomography: results of ex vivo investigations.
OBJECTIVE To evaluate the diagnostic accuracy of 16 slice computed tomography (CT) in determining plaque morphology and composition in an experimental setting. The results were compared with histopathological analysis as the reference standard. METHODS Nine human popliteal arteries derived from amputations because of atherosclerotic disease were investigated with multislice spiral CT (MSCT). ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 71 3 شماره
صفحات -
تاریخ انتشار 2007