Maximal oxygen intake estimated from submaximal heart rate.

نویسندگان

  • C O Dotson
  • M A Caprarola
چکیده

This study investigated the predictability of maximal oxygen intake from three different submaximal heart rates assessed during an initial and follow-up ride on a cycle ergometer. Twenty-four healthy male subjects performed workloads of 600, 750, and 900 kpm's for six minutes on each of two visits to the laboratory. Analysis of variance for a randomised complete blocks design, with subjects constituting blocks, was used to analyse heart rate, estimated maximal oxygen intake, and residual estimated maximal oxygen intake variations among the experimental conditions. Relationships between the actual and estimated maximal oxygen intakes were determined using the Pearson Product-Moment formula of correlation. The average estimated maximal oxygen intake was significantly increased from the first testing occasion to the second. Although errors of estimation decreased significantly (450 ml to 366 ml) in favour of the second testing condition, the decrease was neither consistent with workloads nor subjects. The correlation coefficients were consistently low at 600 kpm for both testing occasions (0.68 and 0.73, respectively), consistently high at 750 kpm (0.82 and 0.84, respectively), and quite variable at 900 kpm (0.71 and 0.84, respectively), indicated that the validity of the nomogram was not consistent with all workloads or testing occasions. Despite these inconsistencies, the nomogram is, for practical purposes, a valid predictor of maximal oxygen consumption.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Training intensities for aerobic exercise determined on untrained healthy men.

The purpose of this study was to determine the aerobic training intensity from the maximal and submaximal running exercise in 21 untrained adult men. To accomplish this, we evaluated the relationship between physiological (oxygen intake and heart rate) and physical parameters (running speed) of training intensity, and determined the training intensity at the submaximal exercise. Oxygen intake a...

متن کامل

Reproducibility of cardiorespiratory measurements during submaximal and maximal running in children.

With the increased use of oxygen consumption measurements in clinical and sporting studies, measurement variability has become more important to both the paediatric clinician and the sports scientist. In this study we assessed the reproducibility of cardiorespiratory measurements during submaximal and maximal running in children. Ten healthy, physically active boys (mean(s.d.) age 10.7(0.71) ye...

متن کامل

Validation of a Quick, Submaximal Tut of Maximal Oxygln Intakf

The purpose of this study was to validate a submaximal treadmill test for prediction of maximal oxygen consumption in fifteen male college students. This objective was accomplished by comparing maximal oxygen intake values recorded during a maximal treadmill test with those predicted from the submaximal test. Comparisons were also made among and between the true and predicted values and those e...

متن کامل

Criterion validation of two submaximal aerobic fitness tests, the self-monitoring Fox-walk test and the Åstrand cycle test in people with rheumatoid arthritis

BACKGROUND Aerobic capacity tests are important to evaluate exercise programs and to encourage individuals to have a physically active lifestyle. Submaximal tests, if proven valid and reliable could be used for estimation of maximal oxygen uptake (VO2max). The purpose of the study was to examine the criterion-validity of the submaximal self-monitoring Fox-walk test and the submaximal Åstrand cy...

متن کامل

Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running

BACKGROUND Wearable sensors enable long-term monitoring of health and wellbeing indicators. An objective evaluation of sensors' accuracy is important, especially for their use in health care. OBJECTIVE The aim of this study was to use a wrist-worn optical heart rate (OHR) device to estimate heart rate (HR), energy expenditure (EE), and maximal oxygen intake capacity (VO2Max) during running an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of sports medicine

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1984