Statistical methods for establishing equivalency of a sampling device to the OSHA standard.
نویسندگان
چکیده
Occupational Safety and Health Administration (OSHA) regulations allow the use of an alternative sampling device for exposure monitoring provided the device has been demonstrated to be equivalent to the standard device. For example, the OSHA standard allows the use of an alternate cotton dust sampler that is equivalent to the Lumsden-Lynch vertical elutriator (VE); also, OSHA defines the accuracy of the monitoring device for measuring airborne chemicals such as benzene and sulfur dioxide. Typically, the OSHA criterion is that 90% of the readings of the sampling device should be within +/- 25% of the readings obtained by the standard device or within +/- 25% of the actual airborne chemical concentration. This article proposes two statistical tests for establishing that an alternative measuring device of airborne chemicals or dust is equivalent to the OSHA standard. The statistical tests are illustrated using an example.
منابع مشابه
Statistical methods for establishing equivalency of several sampling devices.
The problem of comparing several alternate sampling devices to the Occupational Safety and Health Administration (OSHA) standard, or the comparison of several sampling devices among themselves, is considered. A test based on the OSHA criterion that states that "90% of the readings of the sampling device should be within +/- 25% of the readings obtained by the standard" is developed. Type I erro...
متن کاملProviding a model for the possibility of establishing a standard 34,000 human resource management system in Ansar Bank
The present study seeks to provide a model for the possibility of establishing a standard system of 34,000 human resource management and provide a favorable model in Ansar Bank. Managers and experts of Ansar Bank are considered as a statistical population of a small section, which was about 1500 people, is a cluster sampling method. In this study, to estimate the sample size according to the nu...
متن کاملControlled-Release Low Density Effervescent Floating Matrix Tablets of Risperidone: Development, Optimization, in vitro-in vivo Evaluation in Healthy Human Volunteers and Determination of Dissolution Equivalency
The main objective of the present study was to formulate gastroretentive effervescent sustained release drug delivery systems of risperidone floating tablets with the help of Methocel® K15, Ethocel® standard 7FP premium, Eudragit ® RS100 sustained release polymers to improve its safety profile, bioavailability and patient compliance. Risperidone floating tablets were formulated by wet granulati...
متن کاملEfficiency of Canopy Cover Measurement of Artemisia sieberi Stands by Two Sampling Methods in Different Lengths (Case study: Steppe Vegetation of Baft Region, Iran)
This research has been conducted to establish a wheel-point device and evaluate its efficiency (precision, accuracy and time) with respect to the estimation of canopy percent in a pilot Artemisia stand in Khabr region of Baft, Kerman province, Iran in 2015. Several transects with different lengths (30, 60, 90, 120, 150 and 180 m) were established using the randomized sampling block with 5 repli...
متن کاملشبیه سازی آزمون ایمپالس متری VLIP و ارائه روشی برای تعیین معادل TNT انفجاری
The VLIP is a usefull system to compare the high explosives efficiency. This device includes a metallic plate which located above the explosive material and upthrown vertically due to the explosion. The exerted impulse on the plate is used as a meter to determine the explosives efficiency. Since the VLIP system has a low cost, in this paper a method based on VLIP is presented to determine the T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AIHA journal : a journal for the science of occupational and environmental health and safety
دوره 63 5 شماره
صفحات -
تاریخ انتشار 2002