Comparison of Two Cryogenic Radiometers at NIST
نویسندگان
چکیده
Two cryogenic radiometers from NIST, one from the Optical Technology Division and the other from the Optoelectronics Division, were compared at three visible laser wavelengths. For this comparison, each radiometer calibrated two photodiode trap detectors for spectral responsivity. The calibration values for the two trap detectors agreed within the expanded (k = 2) uncertainties. This paper describes the measurement and results of this comparison.
منابع مشابه
Intercomparison of the LBIR Absolute Cryogenic Radiometers to the NIST Optical Power Measurement Standard
The Low Background Infrared calibration (LBIR) facility at the National Institute of Standards and Technology (NIST) presently maintains four absolute cryogenic radiometers (ACRs) which serve as standard reference detectors for infrared calibrations performed by the facility. The primary standard for optical power measurements at NIST-Gaithersburg has been the High Accuracy Cryogenic Radiometer...
متن کاملBilateral NIST-PTB Comparison of Spectral Responsivity in the VUV
To compare the calibration capabilities for the spectral responsivity in the vacuum-ultraviolet spectral region between 135 nm and 250 nm, PTB and NIST agreed on a bilateral comparison. Calibrations of semiconductor photodiodes as transfer detectors were performed using monochromatized synchrotron radiation and cryogenic electrical substitution radiometers as primary detector standards. Great i...
متن کاملRealization of the National Institute of Standards and Technology detector-based spectral irradiance scale.
A detector-based spectral irradiance scale has been realized at the National Institute of Standards and Technology (NIST). Unlike the previous NIST spectral irradiance scales, the new scale is generated with filter radiometers calibrated for absolute spectral power responsivity traceable to the NIST high-accuracy cryogenic radiometer instead of with the gold freezing-point blackbody. The calibr...
متن کاملLow-Background Temperature Calibration of Infrared Blackbodies
The stability of blackbody sources and their ability to be modeled accurately make them well suited for radiometric calibration activity. However, the implementation of the blackbody in industry or the laboratory may, and often does result in blackbody performance that deviates from ideal. The Low Background Infrared (LBIR) facility at the National Institute of Standards and Technology (NIST) w...
متن کاملDevelopments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral irradiance scale to 0.17 % for the range from 350 nm to 1100 nm. To accomplish this goal, a suite ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 106 شماره
صفحات -
تاریخ انتشار 2001