Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture.

نویسندگان

  • Mayank Vijayvargiya
  • Abhishek Pathak
  • Sanjiv Gaur
چکیده

INTRODUCTION Proximal humerus fractures account for approximately 5% of all fractures. Stable minimally displaced fractures can be treated nonoperatively but the management of displaced fractures remain controversial with various modalities of treatment available. Locking plates provide stable fixation and enable early postoperative mobilization specially in osteoporotic proximal humerus fracture. AIM To evaluate the functional outcome of locking plate fixation and to compare the results of two approaches used for fixation. MATERIALS AND METHODS This prospective study was conducted at a tertiary level hospital between September 2011 to December 2013. PHILOS plates were used for internal fixation of displaced proximal humerus fractures Neer's type 2 part, 3 part and 4 part fractures on 26 patients (M/F ratio 1.36:1; mean age 46 years). According to Neer classification, 5,12 and 9 patients had displaced 2, 3 and 4 part fractures respectively. Deltopectoral and deltoid splitting approaches were used for fixation on 13 patients each. Functional outcome was assessed using Constant-Murley shoulder score. Graphpad software version 6.0 was used with Chi-square test and Fisher-exact test are used to compare data. The p-value< 0.05 is considered significant. RESULTS Of the 26 patients, all fractures united radiologically and clinically and average constant score at final follow-up was 72.5. At the final follow-up 8 patients had good score, 10 patients had moderate score, 6 patients had excellent outcome and 2 patients had poor outcome according to Constant score. Mean time to union was 12.3 weeks (9 -15 weeks). Four complications (15.4%) were encountered, 2 cases of varus malunion, 1 case of wound infection which required wound debridement and 1 case of screw cut-out in which screw removal was done. Mean constant score in delto splitting approach was 70.9 and 74 in deltopectoral group (p-value= 0.54). No significant difference existed in constant score in 2 approaches. No significant difference existed between groups in terms of complications (P > .05) and all fractures were united. CONCLUSION Our study demonstrates that locking plate fixation gives good functional outcomes in treatment of proximal humerus fractures. There was no significant difference in the two approaches used for exposure. Our results are comparable to various studies conducted by other authors which states that locking plates provide better functional and radiological outcomes as compared to other fixation methods like Tension band wiring, percutaneous K-wire fixation, non-locking plates, intramedullary nails.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital.

Proximal humerus fractures have been a challenge to achieve stable fixation. PHILOS (Proximal Humerus internal locking system) is part of the latest generation of locking compression plates for proximal humeral fracture fixation. We aim to assess the clinical and functional outcome of proximal humeral fractures (2-part, 3-part and 4-part) treated with the PHILOS plate. We prospectively reviewed...

متن کامل

Locking plate fixation for proximal humerus fractures.

Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for p...

متن کامل

Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.

OBJECTIVE To compare the mechanical stability of a fixed-angle blade plate with that of a locking plate in a cadaveric proximal humerus fracture-fixation model subjected to cyclic loading. A secondary objective was to evaluate whether the use of synthetic humerus specimens would replicate significant differences found during cadaveric tests. DESIGN Mechanical evaluation of constructs in bendi...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Osteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results

UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical and diagnostic research : JCDR

دوره 10 8  شماره 

صفحات  -

تاریخ انتشار 2016