BACKGROUND Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS Of 170 patients referred for ablation of common atrial flutter, conventional ablation of the cavotricuspid isthmus with >21 applications failed to create a bidirectional block in 13 (7.6%). An irrigated-tip catheter ablation was performed on identified gaps in the ablation line according to a protocol found to be safe in animals: a moderate flow rate of 17 mL/min and temperature-controlled (target, 50 degrees C) RF delivery with a power limit of 50 W. Bidirectional isthmus block was achieved in 12 patients by use of a mean delivered power of 40+/-6 W with a single application in 6 patients and 2 to 6 applications in the other 6. No side effects occurred during or after the procedure. CONCLUSIONS Irrigated-tip catheter ablation is safe and effective for achieving cavotricuspid isthmus block when conventional RF energy has failed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter.

BACKGROUND Radiofrequency (RF) ablation of common flutter requires the creation of a complete ablation line to produce bidirectional conduction block in the cavotricuspid isthmus. An irrigated-tip ablation catheter has been shown to be effective in patients in whom conventional ablation has failed. This randomized study compares the efficacy and safety of this catheter with those of a conventio...

متن کامل

Bipolar radiofrequency catheter ablation for refractory perimitral flutter: a case report

BACKGROUND Mitral isthmus is often targeted as a part of stepwise approach during radiofrequency ablation for persistent atrial ablation. Acute success rate in achieving the mitral isthmus block is only modest, late reconduction rate is relatively high and, consequently, incomplete lesion may be proarrhythmic. We describe the first-in-man experience with successful MI ablation by bipolar RF ene...

متن کامل

Remote magnetic navigation for ablation of typical atrial flutter: Long-term results.

INTRODUCTION AND AIM Remote magnetic navigation has proved to be effective in the ablation of most supraventricular and ventricular arrhythmias. Initial studies reported worse results with this system compared to conventional ablation for atrial flutter. The aim of this study was to assess the acute and long-term success of atrial flutter ablation with remote magnetic navigation and to retrospe...

متن کامل

Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter.

AIMS A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl). M...

متن کامل

Flutter ablation with remote magnetic navigation: comparison between the 8-mm tip, the irrigated tip and a manual approach.

INTRODUCTION Remote magnetic navigated ablation has proven its feasibility in a large group of arrhythmias. Until now only scarce data are available on the use for atrial flutter. In this study we compared remote magnetic navigation (RMN), using non-irrigated and irrigated tip catheters, to manual radiofrequency ablation for ablating typical atrial flutter. METHODS The 3 study groups consiste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 98 9  شماره 

صفحات  -

تاریخ انتشار 1998