Prospective motion correction for single-voxel 1H MR spectroscopy.

نویسندگان

  • Brian Keating
  • Weiran Deng
  • J Cooper Roddey
  • Nathan White
  • Anders Dale
  • V Andrew Stenger
  • Thomas Ernst
چکیده

Head motion during (1)H MR spectroscopy acquisitions may compromise the quality and reliability of in vivo metabolite measurements. Therefore, a three-plane image-based motion-tracking module was integrated into a single-voxel (1)H MR spectroscopy (point-resolved spectroscopy) sequence. A series of three orthogonal spiral navigator images was acquired immediately prior to the MR spectroscopy water suppression module in order to estimate head motion. By applying the appropriate rotations and translations, the MR spectroscopy voxel position can be updated such that it remains stationary with respect to the brain. Frequency and phase corrections were applied during postprocessing to reduce line width and restore coherent averaging. Spectra acquired during intentional head motion in 11 volunteers demonstrate reduced lipid contamination and increased spectral reproducibility when motion correction is applied.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-D Prospective Motion Correction for MR Spectroscopy

INTRODUCTION Spectroscopy scans generally require averaging (over minutes) to obtain acceptable signal-to-noise ratio (SNR). Patient motion compromises the quality and reliability of the resulting spectra. Such concerns are particularly acute with subjects who have difficulty holding still, for instance young children or adults who are in pain or confused. Therefore, we implemented a single-vox...

متن کامل

Malignant tumors and chronic infections in the masticator space: preliminary assessment with in vivo single-voxel 1H-MR spectroscopy.

BACKGROUND AND PURPOSE Differential diagnosis between malignant tumors and chronic infections in the masticator space remains challenging. The purpose of the study was to categorize various changes of both lesions by using single-voxel 1H-MR spectroscopy. MATERIALS AND METHODS Twenty-four masticator space lesions, 7 chronic infections, and 17 malignant tumors were assessed with 1H-MR spectros...

متن کامل

1H MR spectroscopy of the brain: absolute quantification of metabolites.

Hydrogen 1 (1H) magnetic resonance (MR) spectroscopy enables noninvasive in vivo quantification of metabolite concentrations in the brain. Currently, metabolite concentrations are most often presented as ratios (eg, relative to creatine) rather than as absolute concentrations. Despite the success of this approach, it has recently been suggested that relative quantification may introduce substan...

متن کامل

Spectroscopic imaging with prospective motion correction and retrospective phase correction.

Motion-induced artifacts are much harder to recognize in magnetic resonance spectroscopic imaging than in imaging experiments and can therefore lead to erroneous interpretation. A method for prospective motion correction based on an optical tracking system has recently been proposed and has already been successfully applied to single voxel spectroscopy. In this work, the utility of prospective ...

متن کامل

Correction of frequency drifts induced by gradient heating in 1H spectra using interleaved reference spectroscopy.

PURPOSE To evaluate the impact of heating-induced frequency drifts on single-voxel spectroscopy and to demonstrate correction strategies based on the interleaved reference scan technique. MATERIALS AND METHODS Frequency drifts induced by gradient heating are assessed for two clinical 3 Tesla (T) whole body MR systems. The interleaved reference scan (IRS) method is used for correcting these fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 64 3  شماره 

صفحات  -

تاریخ انتشار 2010