An independent effect of spatial frequency on motion integration reveals orientation resolution
نویسندگان
چکیده
PROBLEM To investigate the independent role of spatial frequency on component motion integration. METHOD Two Type II plaids were presented at varying spatial frequencies. The velocity vectors of the underlying components were constructed so that predicted speed and direction from the components; the Intersection of Constraints; the vector average; and distortion products, remained constant for each of the two plaids across spatial frequency. Perceived direction was measured using a method of adjustment. RESULTS Perceived direction changed as a function of spatial frequency, approaching the pattern direction only at spatial frequencies greater than 0.5cpd. CONCLUSIONS Spatial frequency has an independent effect on the component integration stage that determines perceived pattern motion direction. The results appear to reflect the resolution of orientation for recombination of the components at low spatial frequencies. These results have implications for motion modelling and possible clinical applications.
منابع مشابه
The spatial frequency and orientation selectivity of the mechanisms that extract motion-defined contours
The human visual system can undertake a specialized form of motion integration, one that enables the presence of extended spatial contours to be disambiguated from their backgrounds. We have shown previously that the visual system can selectively integrate local motion signals when their directions are along spatial contours and its efficiency is inversely related to the curvature of the contou...
متن کاملThe effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملThe effect of earth magnetic field on the function of nuclear medicine imaging systems (SPECT)
Background: The nuclear medicine systems are very sensitive to the variation of the magnetic field. Photomultiplier tubes amplify low energy light signal and change it into electrical current. Low magnetic field can produce some variations in uniformity and special resolution of SPECT systems. In this study, we tried to evaluate the effects of magnetic field on the function of nuclear medic...
متن کاملInvestigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...
متن کاملIntegration Scheme for SINS/GPS System Based on Vertical Channel Decomposition and In-Motion Alignment
Accurate alignment and vertical channel instability play an important role in the strap-down inertial navigation system (SINS), especially in the case that precise navigation has to be achieved over long periods of time. Due to poor initialization as well as the cumulative errors of low-cost inertial measurement units (IMUs), initial alignment is not sufficient to achieve required navigation ac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 50 شماره
صفحات -
تاریخ انتشار 2010