Magnetic resonance cholangiopancreatography: value of using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence.

نویسندگان

  • J T Ho
  • C K Yap
چکیده

The purpose of this study was to evaluate the accuracy of magnetic resonance cholangiopancreatography (MRCP) for visualisation and diagnosis of pancreatico-biliary diseases. Our results of 35 case studies, correlating with results from endoscopic, percutaneous cholangiopancreatography or laparotomy, showed that MRCP performed using the half-Fourier acquisition single-shot turbo spin echo (HASTE) sequences was fast and accurate for depiction of the biliary and pancreatic system, with a diagnostic value comparable to that of direct cholangiography. The presence of biliary obstruction was accurately diagnosed in all but one patient. In hilar strictures, MR cholangiogram was able to depict the intrahepatic biliary tree proximal to the level of obstruction which was not readily displayed by endoscopic retrograde cholangiopancreatography (ERCP) (Figs. 1 & 2). This overview of the entire biliary system was found to be advantageous for preprocedural planning. However, the accuracy for stone detection was limited by the presence of aerobilia from previous sphincterotomy or biliary-enteric anastomosis. Ductal stones less than 3 mm in size within a non-dilated system may be missed due to inadequate spatial resolution. This occurred in a patient with pancreatic duct stones. It is hoped that the accuracy of HASTE magnetic resonance cholangiopancreatography in evaluation of pancreatico-biliary disease would obviate the need for diagnostic invasive cholangiography in selected patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Frequency of common bile duct motion artifacts caused by inferior vena cava pulsation on magnetic resonance cholangiopancreatography.

PURPOSE We assessed the frequency of common bile duct (CBD) motion artifacts caused by inferior vena cava (IVC) pulsation on magnetic resonance cholangiopancreatography (MRCP). METHODS We retrospectively evaluated CBD motion artifacts in 4 MRCP sequences from each of 115 consecutive patients. RESULTS We observed 37 (32.2%) ghost artifacts at the ventral and dorsal aspects of the CBD on tran...

متن کامل

MR Urography in Patients with Acute Flank Pain: Comparison of Gadolinium-Enhanced 3D FLASH After Low-Dose Diuretic with 2D Turbo Spin Echo Sequences

Introduction: Intravenous excretory urography (IVU) has been regarded as the imaging modality of choice for the detection of urinary tract disorders in patients with acute flank pain. Functional as well as anatomical details are provided by this imaging technique. The use of ionised radiation and contrast material (CM) are considered to be the major drawbacks of IVU. Recently, the use of magnet...

متن کامل

Half-fourier acquisition single-shot turbo spin-echo (HASTE) MR: comparison with fast spin-echo MR in diseases of the brain.

PURPOSE To compare an ultrafast T2-weighted (half-Fourier acquisition single-shot turbo spin-echo [HASTE]) pulse sequence with fast spin-echo T2-weighted sequences in MR imaging of brain lesions. METHODS Fast spin-echo and HASTE images of 34 consecutive patients over the age of 50 years or with suspected demyelinating disease were reviewed independently by two neuroradiologists for the number...

متن کامل

MR sialography using half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences.

We describe our preliminary experience with the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences for MR imaging of the salivary gland ducts. In the majority of patients, the main parotid and/or submandibular gland ducts and large branches within the glands were detectable on MR images obtained in 2 seconds per section and within 3 minutes for the entire examination. MR sia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 1999