New method to measure coronary velocity and coronary flow reserve.
نویسندگان
چکیده
Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the reproducibility and accuracy of intravascular conductance catheter-based method for measurements of baseline and hyperemic coronary flow velocity (and hence CFR). The absolute coronary blood velocity was determined by measuring the time of transit of a saline injection between two pairs of electrodes (known distance) on a conductance catheter during a routine saline injection without the need for reference flow. In vitro validation was made in the velocity range of 5 to 70 cm/s in reference to the volume collection method. In 10 swine, velocity measurements were compared with those from a flow probe in coronary arteries at different CFR attained by microsphere embolization. In vitro, the mean difference between the proposed method and volume collection was 0.7 ± 1.34 cm/s for steady flow and -0.77 ± 2.22 cm/s for pulsatile flow. The mean difference between duplicate measurements was 0 ± 1.4 cm/s. In in vivo experiments, the flow (product of velocity and lumen cross-sectional area that is also measured by the conductance catheter) was determined in both normal and stenotic vessels and the mean difference between the proposed method and flow probe was -1 ± 12 ml/min (flow ranged from 10 to 130 ml/min). For CFR, the mean difference between the two methods was 0.06 ± 0.28 (range of 1 to 3). Our results demonstrate the reproducibility and accuracy of velocity and CFR measurements with a conductance catheter by use of a standard saline injection. The ability of the combined measurement of coronary lumen area (as previously validated) and current velocity and CFR measurements provides an integrative diagnostic tool for interventional cardiology.
منابع مشابه
TRANSLATIONAL PHYSIOLOGY New method to measure coronary velocity and coronary flow reserve
Zhang ZD, Svendsen M, Choy JS, Sinha AK, Huo Y, Yoshida K, Molloi S, Kassab GS. New method to measure coronary velocity and coronary flow reserve. Am J Physiol Heart Circ Physiol 301: H21–H28, 2011. First published May 6, 2011; doi:10.1152/ajpheart.00080.2011.—Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the...
متن کاملNon-invasive measurement of coronary flow reserve in children with Kawasaki disease.
OBJECTIVE To investigate whether transthoracic Doppler echocardiography (TTE) can reliably measure the coronary flow reserve in the left anterior descending coronary artery in children with Kawasaki disease. DESIGN Coronary flow velocity in the distal left anterior descending coronary artery was measured by TTE and was compared with that obtained by intracoronary Doppler guide wire. The ratio...
متن کاملFunctional assessment of coronary stenosis: it does make sense, but why don't I do it more often?
and at 6 months follow-up. As in other studies, there was only moderate correlation between coronary flow velocity reserve and diameter stenosis in lesions of moderate severity and the cut-off of coronary flow velocity reserve was 1·9 for patients with intermediate lesions. There are some known limitations with the use of Doppler coronary flow velocity reserve determinations. To obtain a good s...
متن کاملCORONARY BLOOD FLOW Noninvasive Assessment of Coronary Flow Velocity and Coronary Flow Velocity Reserve in the Left Anterior Descending Coronary Artery by Doppler Echocardiography Comparison With Invasive Technique
Objectives. The purpose of this study was to evaluate whether transthoracic Doppler echocardiography (TTDE) can reliably measure coronary flow velocity (CFV) and coronary flow velocity reserve (CFVR) in the left anterior descending coronary artery (LAD) in the clinical setting. Background. Coronary flow velocity measurement has provided useful clinical and physiologic information. Advancement i...
متن کاملNoninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography.
BACKGROUND We hypothesized that coronary blood flow (CBF) reserve could be quantified noninvasively in humans using myocardial contrast echocardiography (MCE). METHODS AND RESULTS Eleven patients with normal epicardial coronary arteries (group I) and 19 with single-vessel coronary stenosis (group II) underwent quantitative coronary angiography, MCE, and CBF velocity measurements at rest and d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 301 1 شماره
صفحات -
تاریخ انتشار 2011